CONINVERS®
Shielded Cable Connectors M23    Series SC-/SI-...
Technical Data
Shell material              
Machined components: Copper-Zinc alloy (CuZn)    
Die cast components: Zinc (GD-Zn)    
Shell plating: Nickel (Ni) plated    
Cable entry: max. 15 mm    
Insulator     
Connector inserts: Polyamid (PA 66) UL 94 V0    
Contacts    
Contact material: Copper-Zinc alloy (CuZn)    
Contact plating: Nickel (Ni) with gold (Au) passivated    
Contact termination: Crimp contacts    
     
Sealing    
Sealing rings: Fluor rubber (FPM), or Perbunan (NBR) stiffened gaskets  
Gaskets: Perbunan (NBR)    
     
Temperature    
Temperature (long term) Celsius: - 40 C  up to  +125 C    
Temperature (long term) Fahrenheit: - 40 F  up to  + 257 F    
Mating    
Threading female coupling nuts: M 23  metric thread 23 mm Ø    
Threading male receptacles: M 23  metric thread 23 mm Ø    
Mating cycles: Standard min. 50    
Protection     SC/SI
Protection class : IP 67/IP 68 (mated) depends on which cable gland is used    Series
 
   
Approvals UL-recognized File No. 153698 (M)  Underwriter Laboratories Inc. ®
   
 
   
     
     
     
         
         
      mating face female   mating face female    
Number of positions     5+PE   4+3+PE    
Number of contacts     6   4         4    
Contact dia. (mm Ø)     2   1        2    
Rated current (A)     26   9       26    
Rated voltage (V)     600   300    600    
Test voltage (Volt  AC)     4,000   2,500  4,000    
Overvoltage category DIN EN 61984-2001     II   II    
Insulation resistance ()     1013   1013    
Contact resistance (m)     3   3    
Pollution degree acc. to IEC 664-1     2 (31)   2 (31)