| PUR - Control - Cable - JZ - 141 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
20AWG (0.5 mm²) Stranding: VDE 295, class 5 (16 x 0,2 mm) |
|
| Machining Centers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control Panels |
141-0005-002 |
2 |
0.19 |
4.9 |
141-0005-018 |
18 |
0.42 |
10.6 |
|
| Control Systems |
141-0005-003 |
3 |
0.21 |
5.2 |
141-0005-025 |
25 |
0.49 |
12.5 |
|
| Machines |
141-0005-004 |
4 |
0.23 |
5.8 |
141-0005-034 |
34 |
0.57 |
14.4 |
|
| Electrical Equipments |
141-0005-005 |
5 |
0.25 |
6.3 |
141-0005-041 |
41 |
0.62 |
15.8 |
|
| |
141-0005-007 |
7 |
0.27 |
6.8 |
|
|
|
|
|
| |
141-0005-010 |
10 |
0.34 |
8.7 |
|
|
|
|
|
| Specifications: |
141-0005-012 |
12 |
0.35 |
9.0 |
|
|
|
|
|
| According to VDE |
18AWG (0.75 mm²) Stranding: VDE 295, class 5 (24 x 0,2 mm) |
|
| 0245, 0250, 0282 |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| |
141-0007-002 |
2 |
0.22 |
5.6 |
141-0007-018 |
18 |
0.48 |
12.2 |
|
| Construction: |
141-0007-003 |
3 |
0.23 |
5.8 |
141-0007-025 |
25 |
0.55 |
14.0 |
|
| Conductors: |
141-0007-004 |
4 |
0.26 |
6.6 |
141-0007-034 |
34 |
0.63 |
15.9 |
|
| bare copper strands acc. to |
141-0007-005 |
5 |
0.29 |
7.3 |
141-0007-041 |
41 |
0.69 |
17.4 |
|
| VDE 0295, class 5, with PVC |
141-0007-007 |
7 |
0.32 |
8.2 |
|
|
|
|
|
| insulation. |
141-0007-012 |
12 |
0.40 |
10.2 |
|
|
|
|
|
| Color code: |
17AWG (1.00 mm²) Stranding: VDE 295, class 5 (32 x 0,2 mm) |
|
| black conductors with consec. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| numbers, cables with three or |
141-0010-002 |
2 |
0.23 |
5.8 |
141-0010-018 |
18 |
0.51 |
13.0 |
|
| more conductors with green/ |
141-0010-003 |
3 |
0.25 |
6.4 |
141-0010-025 |
25 |
0.60 |
15.3 |
|
| yellow ground wire in the
outer |
141-0010-004 |
4 |
0.27 |
6.9 |
141-0010-034 |
34 |
0.67 |
17.1 |
|
| layer. |
141-0010-005 |
5 |
0.30 |
7.5 |
141-0010-041 |
41 |
0.74 |
18.8 |
|
| Stranding: |
141-0010-007 |
7 |
0.33 |
8.3 |
|
|
|
|
|
| cores twisted in layers |
141-0010-009 |
9 |
0.36 |
9.1 |
|
|
|
|
|
| Jacket: |
141-0010-012 |
12 |
0.43 |
11.0 |
|
|
|
|
|
| PUR gray, self-extinguishing, |
16AWG (1.50 mm²) Stranding: VDE 295, class 5 (30 x 0,25 mm) |
|
| flame retardant, Oil
resistant, |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| none-adhesive, resistant to |
141-0015-002 |
2 |
0.25 |
6.4 |
141-0015-018 |
18 |
0.55 |
14.0 |
|
| hydrolysis and microbes. |
141-0015-003 |
3 |
0.26 |
6.7 |
141-0015-025 |
25 |
0.68 |
17.2 |
|
| Technical Data: |
141-0015-004 |
4 |
0.29 |
7.2 |
141-0015-034 |
34 |
0.78 |
19.9 |
|
| Rated voltage: |
141-0015-005 |
5 |
0.32 |
8.1 |
141-0015-041 |
41 |
0.87 |
22.0 |
|
| 300/500 Volt |
141-0015-007 |
7 |
0.35 |
8.9 |
|
|
|
|
|
| Test voltage: |
141-0015-012 |
12 |
0.48 |
12.3 |
|
|
|
|
|
| 3,000 |
14AWG (2.50 mm²) Stranding: VDE 295, class 5 (50 x 0,25 mm) |
|
| Bending radius: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| fixed: 5 x diameter |
141-0025-003 |
3 |
0.33 |
8.3 |
141-0025-007 |
7 |
0.45 |
11.3 |
|
| flexible app.: 12.5 x
diameter |
141-0025-004 |
4 |
0.36 |
9.2 |
141-0025-012 |
12 |
0.60 |
15.1 |
|
| Temperature range: |
141-0025-005 |
5 |
0.41 |
10.3 |
|
|
|
|
|
| fixed: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|