| Shielded - PVC - Control - Cable - JZ - CY - 130 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
12AWG (4.00 mm²) Stranding: VDE 295, class 5 (56 x 0,3 mm) |
|
| Machining Centers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control Panels |
130-0040-004 |
4 |
0.53 |
13.4 |
|
|
|
|
|
| Control Systems |
130-0040-005 |
5 |
0.58 |
14.7 |
|
|
|
|
|
| Machines |
10AWG (6.00 mm²) Stranding: VDE 295, class 5 (84 x 0,3 mm) |
|
| Electrical Equipments |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Whenever elecrical
interference |
130-0060-004 |
4 |
0.63 |
15.9 |
|
|
|
|
|
| distorts signal transmission. |
130-0060-005 |
5 |
0.89 |
22.5 |
|
|
|
|
|
| Specifications: |
8AWG (10.00 mm²) Stranding: VDE 295, class 5 (80 x 0,4 mm) |
|
| According
to VDE |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| 0245, 0281 |
130-0100-004 |
4 |
0.75 |
19.0 |
|
|
|
|
|
| Construction: |
130-0100-005 |
5 |
0.89 |
22.5 |
|
|
|
|
|
| Conductors: |
6AWG (16.00 mm²) Stranding: VDE 295, class 5 (128 x 0,4 mm) |
|
| bare copper strands acc. to |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| VDE 0295, class 5, with PVC |
130-0160-004 |
4 |
0.87 |
22.2 |
|
|
|
|
|
| insulation |
130-0160-005 |
5 |
0.98 |
24.9 |
|
|
|
|
|
| Color code: |
4AWG (25.00 mm²) Stranding: VDE 295, class 5 (200 x 0,4 mm) |
|
| black conductors with consec. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| numbers, cables with three or |
130-0250-004 |
4 |
1.28 |
32.4 |
|
|
|
|
|
| more conductors with green/ |
2AWG (35.00 mm²) Stranding: VDE 295, class 5 (280 x 0,4 mm) |
|
| yellow ground wire in the
outer |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| layer |
130-0350-004 |
4 |
1.39 |
35.4 |
|
|
|
|
|
| Stranding: |
|
|
|
|
|
|
|
|
|
| cores twisted in layers |
|
|
|
|
|
|
|
|
|
| Jacket: |
|
|
|
|
|
|
|
|
|
| inner jacket gray PVC, plus |
|
|
|
|
|
|
|
|
|
| braided common shield with |
|
|
|
|
|
|
|
|
|
| outer jacket PVC transparent. |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Technical Data: |
|
|
|
|
|
|
|
|
|
| Rated voltage: |
|
|
|
|
|
|
|
|
|
| 300/500 Volt |
|
|
|
|
|
|
|
|
|
| Test voltage: |
|
|
|
|
|
|
|
|
|
| 4,000 Volt |
|
|
|
|
|
|
|
|
|
| Bending radius: |
|
|
|
|
|
|
|
|
|
| fixed: 6 x diameter |
|
|
|
|
|
|
|
|
|
| flexible app.: 20 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature range: |
|
|
|
|
|
|
|
|
|
| fixed: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|