| Steel braided - PVC - Control - Cable - JZ - SY - 120 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
16AWG (1.50 mm²) Stranding: VDE 295, class 5 (30 x 0,25 mm) |
|
| Machining Centers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control Panels |
120-0015-025 |
25 |
0.80 |
20.4 |
120-0015-061 |
61 |
1.16 |
29.5 |
|
| Control Systems |
120-0015-034 |
34 |
0.91 |
23.1 |
120-0015-080 |
80 |
1.30 |
33.0 |
|
| Machines |
120-0015-042 |
42 |
0.96 |
24.4 |
120-0015-100 |
100 |
1.41 |
35.7 |
|
| Electrical Equipments |
120-0015-050 |
50 |
1.08 |
27.2 |
|
|
|
|
|
| Whenever high mechanical |
14AWG (2.50 mm²) Stranding: VDE 295, class 5 (50 x 0,25 mm) |
|
| loading capacity is required. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Specifications: |
120-0025-002 |
2 |
0.41 |
10.4 |
120-0025-012 |
12 |
0.72 |
18.4 |
|
| According
to VDE |
120-0025-003 |
3 |
0.44 |
11.2 |
120-0025-018 |
18 |
0.85 |
21.5 |
|
| 0245, 0281 |
120-0025-004 |
4 |
0.47 |
12.5 |
120-0025-025 |
25 |
0.96 |
24.4 |
|
| Construction: |
120-0025-005 |
5 |
0.52 |
13.2 |
120-0025-034 |
34 |
1.10 |
28.1 |
|
| Conductors: |
120-0025-007 |
7 |
0.56 |
14.2 |
|
|
|
|
|
| bare copper strands acc. to |
12AWG (4.00 mm²) Stranding: VDE 295, class 5 (56 x 0,3 mm) |
|
| VDE 0295, class 5, with PVC |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| insulation |
120-0040-003 |
3 |
0.48 |
12.1 |
120-0040-005 |
5 |
0.59 |
15.0 |
|
| Color code: |
120-0040-004 |
4 |
0.56 |
14.2 |
120-0040-007 |
7 |
0.65 |
16.4 |
|
| black conductors with consec. |
10AWG (6.00 mm²) Stranding: VDE 295, class 5 (84 x 0,3 mm) |
|
| numbers, cables with three or |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| more conductors with green/ |
120-0060-004 |
4 |
0.64 |
16.3 |
120-0060-007 |
7 |
0.76 |
19.3 |
|
| yellow ground wire in the
outer |
120-0060-005 |
5 |
0.70 |
17.7 |
|
|
|
|
|
| layer |
8AWG (10.00 mm²) Stranding: VDE 295, class 5 (80 x 0,4 mm) |
|
| Stranding: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| cores twisted in layers |
120-0100-004 |
4 |
0.77 |
19.5 |
120-0100-007 |
7 |
0.92 |
23.4 |
|
| Jacket: |
120-0100-005 |
5 |
0.85 |
21.6 |
|
|
|
|
|
| inner jacket gray PVC, plus |
6AWG (16.00 mm²) Stranding: VDE 295, class 5 (128 x 0,4 mm) |
|
| steel armoured common shield |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| with outer jacket PVC
transpar. |
120-0160-004 |
4 |
0.89 |
22.5 |
120-0160-007 |
7 |
1.08 |
27.3 |
|
| |
120-0160-005 |
5 |
0.97 |
24.7 |
|
|
|
|
|
| Technical Data: |
4AWG (25.00 mm²) Stranding: VDE 295, class 5 (200 x 0,4 mm) |
|
| Rated voltage: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| 300/500 Volt |
120-0250-004 |
4 |
1.14 |
28.9 |
|
|
|
|
|
| Test voltage: |
120-0250-005 |
5 |
1.27 |
32.2 |
|
|
|
|
|
| 4,000 Volt |
2AWG (35.00 mm²) Stranding: VDE 295, class 5 (280 x 0,4 mm) |
|
| Bending radius: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| fixed: 6 x diameter |
120-0350-004 |
4 |
1.33 |
33.7 |
|
|
|
|
|
| flexible app.: 20 x diameter |
120-0350-005 |
5 |
1.49 |
37.8 |
|
|
|
|
|
| Temperature range: |
|
|
|
|
|
|
|
|
|
| fixed: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|