| Shielded - PVC - Control - Cable - LiYCY-JZ-226 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
20AWG (0.5 mm²) Stranding: VDE 295, class 5 (16 x 0,2 mm) |
|
| Machining Centers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control Panels |
226-0005-002 |
2 |
0.22 |
5.7 |
226-0005-018 |
18 |
0.47 |
11.9 |
|
| Control Systems |
226-0005-003 |
3 |
0.23 |
5.9 |
226-0005-020 |
20 |
0.49 |
12.4 |
|
| Machines |
226-0005-004 |
4 |
0.25 |
6.4 |
226-0005-024 |
24 |
0.54 |
13.6 |
|
| Electrical Equipments |
226-0005-005 |
5 |
0.28 |
7.0 |
226-0005-025 |
25 |
0.55 |
13.9 |
|
| Whenever electrical
interference |
226-0005-006 |
6 |
0.30 |
7.7 |
226-0005-030 |
30 |
0.57 |
14.5 |
|
| distorts signal transmission. |
226-0005-007 |
7 |
0.30 |
7.7 |
226-0005-040 |
40 |
0.67 |
16.9 |
|
| Specifications: |
226-0005-008 |
8 |
0.33 |
8.3 |
226-0005-050 |
50 |
0.75 |
19.0 |
|
| According
to VDE |
226-0005-010 |
10 |
0.38 |
9.6 |
226-0005-061 |
61 |
0.82 |
20.8 |
|
| 0281, 0812 |
226-0005-012 |
12 |
0.39 |
9.9 |
|
|
|
|
|
| Construction: |
226-0005-016 |
16 |
0.45 |
11.5 |
|
|
|
|
|
| Conductors: |
18AWG (0.75 mm²) Stranding: VDE 295, class 5 (24 x 0,2 mm) |
|
| bare copper strands acc. to |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| VDE 0295, class 5, with PVC |
226-0007-002 |
2 |
0.24 |
6.1 |
226-0007-020 |
20 |
0.53 |
13.5 |
|
| insulation |
226-0007-003 |
3 |
0.25 |
6.4 |
226-0007-024 |
24 |
0.60 |
15.4 |
|
| Color code: |
226-0007-004 |
4 |
0.28 |
7.0 |
226-0007-030 |
30 |
0.63 |
16.1 |
|
| black conductors with consec. |
226-0007-005 |
5 |
0.30 |
7.7 |
226-0007-032 |
32 |
0.63 |
16.1 |
|
| numbers, cables with three or |
226-0007-006 |
6 |
0.33 |
8.3 |
226-0007-036 |
36 |
0.70 |
17.7 |
|
| more conductors with green/ |
226-0007-007 |
7 |
0.33 |
8.3 |
226-0007-040 |
40 |
0.73 |
18.6 |
|
| yellow ground wire in the
outer |
226-0007-008 |
8 |
0.36 |
9.1 |
226-0007-042 |
42 |
0.79 |
20.1 |
|
| layer |
226-0007-010 |
10 |
0.41 |
10.4 |
226-0007-050 |
50 |
0.83 |
21.0 |
|
| Stranding: |
226-0007-012 |
12 |
0.43 |
10.9 |
226-0007-061 |
61 |
0.93 |
23.7 |
|
| cores twisted in layers |
226-0007-014 |
14 |
0.46 |
11.7 |
|
|
|
|
|
| Jacket: |
226-0007-016 |
16 |
0.48 |
12.3 |
|
|
|
|
|
| PVC gray, with common shield |
226-0007-018 |
18 |
0.50 |
12.7 |
|
|
|
|
|
| and foil between wires and |
17AWG (1.00 mm²) Stranding: VDE 295, class 5 (32 x 0,2 mm) |
|
| the braided screen, self- |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| extinguishing and flame
retardant. |
226-0010-002 |
2 |
0.26 |
6.6 |
226-0010-020 |
20 |
0.58 |
14.8 |
|
| Technical Data: |
226-0010-003 |
3 |
0.27 |
6.9 |
226-0010-024 |
24 |
0.66 |
16.8 |
|
| Rated voltage: |
226-0010-004 |
4 |
0.30 |
7.6 |
226-0010-025 |
25 |
0.67 |
17.1 |
|
| 300/500 Volt |
226-0010-005 |
5 |
0.32 |
8.2 |
226-0010-030 |
30 |
0.70 |
17.8 |
|
| Test voltage: |
226-0010-006 |
6 |
0.36 |
9.2 |
226-0010-034 |
34 |
0.84 |
21.5 |
|
| 2,000 Volt |
226-0010-007 |
7 |
0.36 |
9.2 |
226-0010-040 |
40 |
0.91 |
23.2 |
|
| Bending radius: |
226-0010-008 |
8 |
0.40 |
10.1 |
226-0010-042 |
42 |
0.91 |
23.2 |
|
| fixed: 5 x diameter |
226-0010-010 |
10 |
0.46 |
11.6 |
226-0010-050 |
50 |
0.97 |
24.7 |
|
| flexible app.: 15 x diameter |
226-0010-012 |
12 |
0.47 |
11.9 |
226-0010-061 |
61 |
1.08 |
27.3 |
|
| Temperature range: |
226-0010-014 |
14 |
0.50 |
12.7 |
|
|
|
|
|
| fixed: -22°F to 176°F |
226-0010-016 |
16 |
0.52 |
13.1 |
|
|
|
|
|
| flex.: 23°F to 158°F |
226-0010-018 |
18 |
0.55 |
13.9 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|