| Shielded - PVC - Control - Cable - LiYCY-JZ-226 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
16AWG (1.50 mm²) Stranding: VDE 295, class 5 (30 x 0,25 mm) |
|
| Machining Centers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control Panels |
226-0015-002 |
2 |
0.31 |
7.8 |
226-0015-018 |
18 |
0.67 |
16.9 |
|
| Control Systems |
226-0015-003 |
3 |
0.32 |
8.1 |
226-0015-020 |
20 |
0.70 |
17.8 |
|
| Machines |
226-0015-004 |
4 |
0.35 |
8.9 |
226-0015-024 |
24 |
0.79 |
20.0 |
|
| Electrical Equipments |
226-0015-005 |
5 |
0.38 |
9.7 |
226-0015-025 |
25 |
0.79 |
20.0 |
|
| Whenever electrical
interference |
226-0015-006 |
6 |
0.42 |
10.7 |
226-0015-030 |
30 |
0.82 |
20.7 |
|
| distorts signal transmission. |
226-0015-007 |
7 |
0.42 |
10.7 |
226-0015-035 |
35 |
0.92 |
23.3 |
|
| Specifications: |
226-0015-008 |
8 |
0.46 |
11.7 |
226-0015-040 |
40 |
1.01 |
25.5 |
|
| According
to VDE |
226-0015-010 |
10 |
0.54 |
13.6 |
226-0015-050 |
50 |
1.09 |
27.4 |
|
| 0281, 0812 |
226-0015-012 |
12 |
0.55 |
14.0 |
226-0015-061 |
61 |
1.15 |
29.1 |
|
| Construction: |
226-0015-014 |
14 |
0.61 |
15.4 |
|
|
|
|
|
| Conductors: |
226-0015-016 |
16 |
0.63 |
16.1 |
|
|
|
|
|
| bare copper strands acc. to |
14AWG (2.50 mm²) Stranding: VDE 295, class 5 (50 x 0,25 mm) |
|
| VDE 0295, class 5, with PVC |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| insulation |
226-0025-002 |
2 |
0.34 |
8.6 |
226-0025-007 |
7 |
0.53 |
13.5 |
|
| Color code: |
226-0025-003 |
3 |
0.37 |
9.5 |
226-0025-012 |
12 |
0.66 |
16.7 |
|
| black conductors with consec. |
226-0025-004 |
4 |
0.40 |
10.2 |
|
|
|
|
|
| numbers, cables with three or |
226-0025-005 |
5 |
0.45 |
11.5 |
|
|
|
|
|
| more conductors with green/ |
12AWG (4.00 mm²) Stranding: VDE 295, class 5 (56 x 0,3 mm) |
|
| yellow ground wire in the
outer |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| layer |
226-0040-002 |
2 |
0.43 |
11.0 |
226-0040-005 |
5 |
0.57 |
14.5 |
|
| Stranding: |
226-0040-003 |
3 |
0.46 |
11.6 |
226-0040-007 |
7 |
0.63 |
16.0 |
|
| cores twisted in layers |
226-0040-004 |
4 |
0.51 |
13.0 |
|
|
|
|
|
| Jacket: |
10AWG (6.00 mm²) Stranding: VDE 295, class 5 (84 x 0,3 mm) |
|
| PVC gray, with common shield |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| and foil between wires and |
226-0060-002 |
2 |
0.48 |
12.1 |
226-0060-005 |
5 |
0.65 |
16.5 |
|
| the braided screen, self- |
226-0060-003 |
3 |
0.53 |
13.4 |
226-0060-007 |
7 |
0.72 |
18.2 |
|
| extinguishing and flame
retardant. |
226-0060-004 |
4 |
0.59 |
15.0 |
|
|
|
|
|
| Technical Data: |
8AWG (10.00 mm²) Stranding: VDE 295, class 5 (80 x 0,4 mm) |
|
| Rated voltage: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| 300/500 Volt |
226-0100-002 |
2 |
0.62 |
15.7 |
226-0100-005 |
5 |
0.81 |
20.6 |
|
| Test voltage: |
226-0100-003 |
3 |
0.66 |
16.7 |
226-0100-007 |
7 |
0.90 |
22.8 |
|
| 2,000 Volt |
226-0100-004 |
4 |
0.72 |
18.4 |
|
|
|
|
|
| Bending radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x diameter |
|
|
|
|
|
|
|
|
|
| flexible app.: 15 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature range: |
|
|
|
|
|
|
|
|
|
| fixed: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|