| Shielded - PVC - Control - Cable - JZ - CY - 168 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
20AWG (0.5 mm²) Stranding: VDE 295, class 5 (16 x 0,2 mm) |
|
| Machining Centers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control Panels |
168-20-02 |
2 |
0.33 |
8.3 |
168-20-18 |
18 |
0.64 |
16.2 |
|
| Control Systems |
168-20-03 |
3 |
0.34 |
8.5 |
168-20-25 |
25 |
0.79 |
20.0 |
|
| Machines |
168-20-04 |
4 |
0.36 |
9.2 |
168-20-34 |
34 |
0.91 |
23.0 |
|
| Electrical Equipments |
168-20-05 |
5 |
0.40 |
10.0 |
168-20-41 |
41 |
0.95 |
24.0 |
|
| Whenever electrical
interference |
168-20-07 |
7 |
0.45 |
11.4 |
|
|
|
|
|
| distorts signal transmission. |
168-20-09 |
9 |
0.46 |
11.6 |
|
|
|
|
|
| Specifications: |
168-20-12 |
12 |
0.57 |
14.5 |
|
|
|
|
|
| UL: AWM-Style 1012/2587 |
19AWG (0.75 mm²) Stranding: VDE 295, class 5 (24 x 0,2 mm) |
|
| CSA: AWM I A/B, II A/B FT 1 |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Construction: |
168-19-02 |
2 |
0.34 |
8.6 |
168-19-18 |
18 |
0.67 |
16.9 |
|
| Conductors: |
168-19-03 |
3 |
0.36 |
9.3 |
168-19-25 |
25 |
0.85 |
21.5 |
|
| bare copper strands acc. to |
168-19-04 |
4 |
0.40 |
10.2 |
168-19-34 |
34 |
0.93 |
23.7 |
|
| VDE 0295, class 5, with PVC |
168-19-05 |
5 |
0.43 |
10.9 |
168-19-41 |
41 |
0.97 |
24.5 |
|
| insulation |
168-19-07 |
7 |
0.51 |
12.9 |
|
|
|
|
|
| Color code: |
168-19-09 |
9 |
0.53 |
13.4 |
|
|
|
|
|
| black conductors with consec. |
168-19-12 |
12 |
0.56 |
14.3 |
|
|
|
|
|
| numbers, cables with three or |
18AWG (1.00 mm²) Stranding: VDE 295, class 5 (32 x 0,2 mm) |
|
| more conductors with green/ |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| yellow ground wire in the
outer |
168-18-02 |
2 |
0.35 |
8.9 |
168-18-12 |
12 |
0.66 |
16.8 |
|
| layer |
168-18-03 |
3 |
0.37 |
9.5 |
168-18-18 |
18 |
0.71 |
18.0 |
|
| Stranding: |
168-18-04 |
4 |
0.40 |
10.1 |
168-18-25 |
25 |
0.87 |
22.00 |
|
| cores twisted in layers |
168-18-05 |
5 |
0.44 |
11.1 |
168-18-34 |
34 |
1.01 |
25.6 |
|
| Jacket: |
168-18-07 |
7 |
0.52 |
13.2 |
168-18-41 |
41 |
1.05 |
26.6 |
|
| Inner jacket PVC gray, plus |
168-18-09 |
9 |
0.60 |
15.1 |
|
|
|
|
|
| common braided shield with PVC |
16AWG (1.50 mm²) Stranding: VDE 295, class 5 (30 x 0,25 mm) |
|
| outer jacket gray,
self-extinguising, |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| flame retardant acc. IEC
332-1 and |
168-16-02 |
2 |
0.40 |
10.2 |
168-16-18 |
18 |
0.82 |
20.8 |
|
| oil
restistant. |
168-16-03 |
3 |
0.43 |
10.9 |
168-16-25 |
25 |
1.06 |
26.8 |
|
| Technical Data: |
168-16-04 |
4 |
0.47 |
11.9 |
168-16-34 |
34 |
1.16 |
29.5 |
|
| Rated voltage: |
168-16-05 |
5 |
0.52 |
13.2 |
168-16-41 |
41 |
1.22 |
30.7 |
|
| 600 Volt |
168-16-07 |
7 |
0.62 |
15.7 |
|
|
|
|
|
| Test voltage: |
168-16-09 |
9 |
0.67 |
17.0 |
|
|
|
|
|
| 3,000 Volt |
168-16-12 |
12 |
0.74 |
18.7 |
|
|
|
|
|
| Bending radius: |
14AWG (2.50 mm²) Stranding: VDE 295, class 5 (50 x 0,25 mm) |
|
| fixed: 5 x diameter |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| flexible app.: 15 x diameter |
168-14-02 |
2 |
0.46 |
11.6 |
168-14-09 |
9 |
0.80 |
20.4 |
|
| Temperature range: |
168-14-03 |
3 |
0.48 |
12.1 |
168-14-12 |
12 |
0.87 |
22.0 |
|
| fixed: -40°F to 194°F |
168-14-04 |
4 |
0.53 |
13.4 |
168-14-18 |
18 |
1.00 |
25.3 |
|
| flex.: 23°F to 194°F |
168-14-05 |
5 |
0.57 |
14.4 |
|
|
|
|
|
| |
168-14-07 |
7 |
0.69 |
17.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|