| Shielded - PVC - Control - Cable - JZ - CY - 168 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
12AWG (4.00 mm²) Stranding: VDE 295, class 5 (56 x 0,3 mm) |
|
| Machining Centers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control Panels |
168-12-03 |
3 |
0.50 |
12.8 |
168-12-07 |
7 |
0.69 |
17.4 |
|
| Control Systems |
168-12-04 |
4 |
0.53 |
13.5 |
|
|
|
|
|
| Machines |
168-12-05 |
5 |
0.58 |
14.6 |
|
|
|
|
|
| Electrical Equipments |
10AWG (6.00 mm²) Stranding: VDE 295, class 5 (84 x 0,3 mm) |
|
| Whenever electrical
interference |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| distorts signal transmission. |
168-10-03 |
3 |
0.66 |
16.6 |
168-10-07 |
7 |
0.82 |
20.9 |
|
| Specifications: |
168-10-04 |
4 |
0.69 |
17.5 |
|
|
|
|
|
| UL: AWM-Style 1012/2587 |
168-10-05 |
5 |
0.73 |
18.5 |
|
|
|
|
|
| CSA: AWM I A/B, II A/B FT 1 |
8AWG (10.00 mm²) Stranding: VDE 295, class 5 (80 x 0,4 mm) |
|
| Construction: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Conductors: |
168-08-03 |
3 |
0.68 |
17.2 |
168-08-07 |
7 |
1.02 |
26 |
|
| bare copper strands acc. to |
168-08-04 |
4 |
0.80 |
20.4 |
|
|
|
|
|
| VDE 0295, class 5, with PVC |
168-08-05 |
5 |
0.87 |
22.0 |
|
|
|
|
|
| insulation |
6AWG (16.00 mm²) Stranding: VDE 295, class 5 (128 x 0,4 mm) |
|
| Color code: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| black conductors with consec. |
168-06-03 |
3 |
0.93 |
23.6 |
168-06-07 |
7 |
1.27 |
32.0 |
|
| numbers, cables with three or |
168-06-04 |
4 |
1.02 |
25.8 |
|
|
|
|
|
| more conductors with green/ |
168-06-05 |
5 |
1.15 |
29.0 |
|
|
|
|
|
| yellow ground wire in the
outer |
4AWG (25.00 mm²) Stranding: VDE 295, class 5 (200 x 0,4 mm) |
|
| layer |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Stranding: |
168-04-03 |
3 |
1.12 |
28.0 |
168-04-07 |
7 |
1.54 |
39.00 |
|
| cores twisted in layers |
168-04-04 |
4 |
1.19 |
30.2 |
|
|
|
|
|
| Jacket: |
168-04-05 |
5 |
1.35 |
34.0 |
|
|
|
|
|
| Inner jacket PVC gray, plus |
2AWG (35.00 mm²) Stranding: VDE 295, class 5 (280 x 0,4 mm) |
|
| common braided shield with
PVC |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| outer jacket gray,
self-extinguising, |
168-02-03 |
3 |
1.19 |
30.0 |
168-02-05 |
5 |
1.46 |
37 |
|
| flame retardant acc. IEC
332-1 and |
168-02-04 |
4 |
1.27 |
32.0 |
|
|
|
|
|
| oil
restistant. |
|
|
|
|
|
|
|
|
|
| Technical Data: |
|
|
|
|
|
|
|
|
|
| Rated voltage: |
|
|
|
|
|
|
|
|
|
| 600 Volt |
|
|
|
|
|
|
|
|
|
| Test voltage: |
|
|
|
|
|
|
|
|
|
| 3,000 Volt |
|
|
|
|
|
|
|
|
|
| Bending radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x diameter |
|
|
|
|
|
|
|
|
|
| flexible app.: 15 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature range: |
|
|
|
|
|
|
|
|
|
| fixed: -40°F to 194°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 194°F |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|