Shielded - PVC - Control - Cable - JB -CY - 131
 
               
 
 
       
           
           
with filler if necessary                
Applications: 20AWG (0.5 mm²) Stranding: VDE 295, class 5  (16 x 0,2 mm)
Machining Centers Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Control Panels 131-0005-002 2 0.27 6.8 131-0005-005 5 0.34 8.5
Control Systems 131-0005-003 3 0.29 7.3        
Machines 131-0005-004 4 0.31 7.8        
Electrical Equipments 18AWG (0.75 mm²) Stranding: VDE 295, class 5  (24 x 0,2 mm)
Whenever electrical interferenece Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
distorts signal transmission. 131-0007-002 2 0.29 7.4 131-0007-005 5 0.35 9.0
Specifications: 131-0007-003 3 0.31 7.8        
According to VDE  131-0007-004 4 0.33 8.4        
0245, 0281 17AWG (1.00 mm²) Stranding: VDE 295, class 5  (32 x 0,2 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 131-0010-002 2 0.31 7.8 131-0010-005 5 0.38 9.6
bare copper strands acc. to 131-0010-003 3 0.32 8.2        
VDE 0295, class 5, with PVC 131-0010-004 4 0.34 8.7        
insulation 16AWG (1.50 mm²) Stranding: VDE 295, class 5  (30 x 0,25 mm)
Color code: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
acc. to VDE 0293 131-0015-002 2 0.34 8.5 131-0015-005 5 0.41 10.5
2 wires: bk,bl 131-0015-003 3 0.35 9.0        
3 wires: gn/yell,bk,bl 131-0015-004 4 0.39 10.0        
4 wires: gn/yell,bk,bl,bn 14AWG (2.50 mm²) Stranding: VDE 295, class 5  (50 x 0,25 mm)
5 wires: gn/yell,bk,bl,bn,bk Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Stranding: 131-0025-003 3 0.41 10.3 131-0025-005 5 0.50 12.7
cores twisted in layers 131-0025-004 4 0.44 11.2        
Jacket: 12AWG (4.00 mm²) Stranding: VDE 295, class 5  (56 x 0,3 mm)
Inner jacket gray PVC, plus  Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
common braided screen and 131-0040-004 4 0.53 13.4        
with outer jacket PVC transpar. 131-0040-005 5 0.58 14.7        
flame ret. and self-extinguishing. 10AWG (6.00 mm²) Stranding: VDE 295, class 5  (84 x 0,3 mm)
Technical Data: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Rated voltage: 131-0060-004 4 0.63 15.9        
up to 1,0 mm² 300/500 Volt 131-0060-005 5 0.68 17.3        
1,5 mm² and up  450/750 Volt 8AWG (10.00 mm²) Stranding: VDE 295, class 5  (80 x 0,4 mm)
Test voltage: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
4,000 Volt 131-0100-004 4 0.75 19.0        
Bending radius: 131-0100-005 5 0.89 22.5        
fixed: 6 x diameter 6AWG (16.00 mm²) Stranding: VDE 295, class 5  (128 x 0,4 mm)
flexible app.: 20 x diameter Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Temperature range: 131-0160-004 4 0.87 22.2        
fixed:  -22°F to 176°F  131-0160-005 5 0.98 24.9        
flex.:    23°F to 158°F