| Steel braided - PVC - Control - Cable - JB -SY - 121 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
20AWG (0.5 mm²) Stranding: VDE 295, class 5 (16 x 0,2 mm) |
|
| Machining Centers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control Panels |
121-0005-002 |
2 |
0.30 |
7.7 |
121-0005-005 |
5 |
0.36 |
9.2 |
|
| Control Systems |
121-0005-003 |
3 |
0.32 |
8.1 |
|
|
|
|
|
| Machines |
121-0005-004 |
4 |
0.34 |
8.6 |
|
|
|
|
|
| Electrical Equipments |
18AWG (0.75 mm²) Stranding: VDE 295, class 5 (24 x 0,2 mm) |
|
| Whenever high mechanical |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| loading capacity is required. |
121-0007-002 |
2 |
0.32 |
8.1 |
121-0007-005 |
5 |
0.39 |
9.9 |
|
| Specifications: |
121-0007-003 |
3 |
0.34 |
8.5 |
|
|
|
|
|
| According
to VDE |
121-0007-004 |
4 |
0.37 |
9.4 |
|
|
|
|
|
| 0245, 0281 |
17AWG (1.00 mm²) Stranding: VDE 295, class 5 (32 x 0,2 mm) |
|
| Construction: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Conductors: |
121-0010-002 |
2 |
0.34 |
8.7 |
121-0010-005 |
5 |
0.40 |
10.2 |
|
| bare copper strands acc. to |
121-0010-003 |
3 |
0.35 |
8.8 |
|
|
|
|
|
| VDE 0295, class 5, with PVC |
121-0010-004 |
4 |
0.38 |
9.6 |
|
|
|
|
|
| insulation |
16AWG (1.50 mm²) Stranding: VDE 295, class 5 (30 x 0,25 mm) |
|
| Color code: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| acc. to VDE 0293 |
121-0015-002 |
2 |
0.36 |
9.3 |
121-0015-005 |
5 |
0.44 |
11.2 |
|
| 2 wires: bk,bl |
121-0015-003 |
3 |
0.39 |
9.8 |
|
|
|
|
|
| 3 wires: gn/yell,bk,bl |
121-0015-004 |
4 |
0.40 |
10.2 |
|
|
|
|
|
| 4 wires: gn/yell,bk,bl,bn |
14AWG (2.50 mm²) Stranding: VDE 295, class 5 (50 x 0,25 mm) |
|
| 5 wires: gn/yell,bk,bl,bn,bk |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Stranding: |
121-0025-002 |
2 |
0.48 |
12.1 |
121-0025-005 |
5 |
0.60 |
15.2 |
|
| cores twisted in layers |
121-0025-003 |
3 |
0.50 |
12.6 |
|
|
|
|
|
| Jacket: |
121-0025-004 |
4 |
0.55 |
13.9 |
|
|
|
|
|
| Inner jacket gray PVC, plus |
12AWG (4.00 mm²) Stranding: VDE 295, class 5 (56 x 0,3 mm) |
|
| steel armoured common shield |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| with outer jacket PVC
transparent, |
121-0040-003 |
3 |
0.58 |
14.6 |
121-0040-005 |
5 |
0.68 |
17.3 |
|
| flame ret. and
self-extinguishing. |
121-0040-004 |
4 |
0.62 |
15.7 |
|
|
|
|
|
| Technical Data: |
10AWG (6.00 mm²) Stranding: VDE 295, class 5 (84 x 0,3 mm) |
|
| Rated voltage: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| up to 1,0 mm² 300/500 Volt |
121-0060-003 |
3 |
0.62 |
15.8 |
121-0060-005 |
5 |
0.74 |
18.8 |
|
| 1,5 mm² and up 450/750 Volt |
121-0060-004 |
4 |
0.68 |
17.3 |
|
|
|
|
|
| Test voltage: |
8AWG (10.00 mm²) Stranding: VDE 295, class 5 (80 x 0,4 mm) |
|
| 4,000 Volt |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Bending radius: |
121-0100-004 |
4 |
0.84 |
21.1 |
|
|
|
|
|
| fixed: 6 x diameter |
121-0100-005 |
5 |
0.91 |
23.1 |
|
|
|
|
|
| flexible app.: 20 x diameter |
6AWG (16.00 mm²) Stranding: VDE 295, class 5 (128 x 0,4 mm) |
|
| Temperature range: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| fixed: -22°F to 176°F |
121-0160-004 |
4 |
0.94 |
23.8 |
|
|
|
|
|
| flex.: 23°F to 158°F |
121-0160-005 |
5 |
1.06 |
26.7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|