| Shielded Halogen-free - Control - Cable - H-CH-1130 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
10AWG (6.00 mm²) Stranding: VDE 295, class 5 (84 x 0,3 mm) |
|
| Machining Centers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control Panels |
1-130-0060-002-5 |
2 |
0.49 |
12.5 |
1-130-0060-005-5 |
5 |
0.65 |
16.5 |
|
| Control Systems |
1-130-0060-003-5 |
3 |
0.52 |
13.3 |
1-130-0060-007-5 |
7 |
0.72 |
18.2 |
|
| Machines |
1-130-0060-004-5 |
4 |
0.59 |
15.0 |
|
|
|
|
|
| Whenever electrical
interference |
8AWG (10.00 mm²) Stranding: VDE 295, class 5 (80 x 0,4 mm) |
|
| distorts signal transmission. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Specifications: |
1-130-0100-002-5 |
2 |
0.62 |
15.8 |
1-130-0100-005-5 |
5 |
0.82 |
20.8 |
|
| According
to VDE |
1-130-0100-003-5 |
3 |
0.66 |
16.8 |
1-130-0100-007-5 |
7 |
0.91 |
23.0 |
|
| 0245, 0250, 0281, 0282, |
1-130-0100-004-5 |
4 |
0.73 |
18.5 |
|
|
|
|
|
| CEI 20.22 |
6AWG (16.00 mm²) Stranding: VDE 295, class 5 (128 x 0,4 mm) |
|
| Construction: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Conductors: |
1-130-0160-004-5 |
4 |
0.87 |
22.0 |
|
|
|
|
|
| bare copper strands acc. to |
1-130-0160-005-5 |
5 |
0.95 |
24.1 |
|
|
|
|
|
| VDE 0295, class 5, with |
|
|
|
|
|
|
|
|
|
| halogen-free
polymer |
|
|
|
|
|
|
|
|
|
| insulation. |
|
|
|
|
|
|
|
|
|
| Color code: |
|
|
|
|
|
|
|
|
|
| black conductors with consec. |
|
|
|
|
|
|
|
|
|
| numbers, cables with three or |
|
|
|
|
|
|
|
|
|
| more conductors with green/ |
|
|
|
|
|
|
|
|
|
| yellow ground wire in the |
|
|
|
|
|
|
|
|
|
| outer layer |
|
|
|
|
|
|
|
|
|
| Stranding: |
|
|
|
|
|
|
|
|
|
| cores twisted in layers |
|
|
|
|
|
|
|
|
|
| Jacket: |
|
|
|
|
|
|
|
|
|
| Specially formulated halogen |
|
|
|
|
|
|
|
|
|
| free polymer blend, gray,
self- |
|
|
|
|
|
|
|
|
|
| extinguishing, flame retardant, |
|
|
|
|
|
|
|
|
|
| with foil around inner
conductors. |
|
|
|
|
|
|
|
|
|
| Technical Data: |
|
|
|
|
|
|
|
|
|
| Rated voltage: |
|
|
|
|
|
|
|
|
|
| 300/500 Volt |
|
|
|
|
|
|
|
|
|
| Test voltage: |
|
|
|
|
|
|
|
|
|
| 3,000 |
|
|
|
|
|
|
|
|
|
| Bending radius: |
|
|
|
|
|
|
|
|
|
| fixed: 6 x diameter |
|
|
|
|
|
|
|
|
|
| flexible app.: 20 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature range: |
|
|
|
|
|
|
|
|
|
| fixed: -40°F
to 176°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|