| Shielded PVC -
Data - Cable - LiYCY-CY-(TP) - 241 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
26AWG (0,14 mm²) Stranding: VDE 295, class 5 (18 x 0,1 mm) |
|
| Sensor Technology |
Part Numbers |
pairs |
O.D. inches |
O.D. mm |
Part Numbers |
pairs |
O.D. inches |
O.D. mm |
|
| Computers |
241-0001-002 |
2 |
0.30 |
7.5 |
241-0001-009 |
9 |
0.55 |
14.0 |
|
| Measurement devices |
241-0001-003 |
3 |
0.31 |
7.8 |
241-0001-010 |
10 |
0.55 |
14.0 |
|
| Control devices |
241-0001-004 |
4 |
0.37 |
9.5 |
241-0001-012 |
12 |
0.60 |
15.1 |
|
| Whenever electrical
interference |
241-0001-005 |
5 |
0.41 |
10.5 |
241-0001-016 |
16 |
0.68 |
17.2 |
|
| distorts signal transmission. |
241-0001-006 |
6 |
0.43 |
11.0 |
241-0001-020 |
20 |
0.70 |
17.8 |
|
| Specifications: |
241-0001-007 |
7 |
0.43 |
11.0 |
|
|
|
|
|
| According
to VDE |
241-0001-008 |
8 |
0.51 |
13.0 |
|
|
|
|
|
| 0281, 0812 |
24AWG (0,25 mm²) Stranding: VDE 295, class 5 (14 x 0,15 mm) |
|
| |
Part Numbers |
pairs |
O.D. inches |
O.D. mm |
Part Numbers |
pairs |
O.D. inches |
O.D. mm |
|
| Construction: |
241-0002-002 |
2 |
0.38 |
9.7 |
241-0002-010 |
10 |
0.65 |
16.6 |
|
| Conductors: |
241-0002-003 |
3 |
0.39 |
10.0 |
241-0002-012 |
12 |
0.67 |
17.0 |
|
| bare copper strands acc. to |
241-0002-004 |
4 |
0.48 |
12.1 |
241-0002-016 |
16 |
0.83 |
21.0 |
|
| VDE 0295, class 5, with PVC |
241-0002-005 |
5 |
0.48 |
12.3 |
241-0002-020 |
20 |
0.89 |
22.6 |
|
| insulation |
241-0002-006 |
6 |
0.52 |
13.2 |
241-0002-024 |
24 |
1.09 |
27.5 |
|
| Color code: |
241-0002-007 |
7 |
0.52 |
13.2 |
|
|
|
|
|
| acc. to DIN 47100 |
241-0002-008 |
8 |
0.61 |
15.5 |
|
|
|
|
|
| see color code table |
|
|
|
|
|
|
|
|
|
| Stranding: |
|
|
|
|
|
|
|
|
|
| cores twisted in pairs, pairs |
|
|
|
|
|
|
|
|
|
| twisted in layers, shield
around |
|
|
|
|
|
|
|
|
|
| pairs with foil and inner
jacket, |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Jacket: |
|
|
|
|
|
|
|
|
|
| outer PVC jacket, gray, with |
|
|
|
|
|
|
|
|
|
| common braided shield, self- |
|
|
|
|
|
|
|
|
|
| extinguishing and flame
retardant |
|
|
|
|
|
|
|
|
|
| Technical Data: |
|
|
|
|
|
|
|
|
|
| Rated voltage: |
|
|
|
|
|
|
|
|
|
| 300 Volt |
|
|
|
|
|
|
|
|
|
| Test voltage: |
|
|
|
|
|
|
|
|
|
| 1,200 Volt |
|
|
|
|
|
|
|
|
|
| Bending radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x diameter |
|
|
|
|
|
|
|
|
|
| flexible app.: 15 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature range: |
|
|
|
|
|
|
|
|
|
| fixed: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|