| Shielded PVC -
Data - Cable - LiFYCY-(TP) - 244 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
|
|
|
|
|
|
|
| Applications: |
28AWG (0,08 mm²) Stranding: VDE
0295, class 6 (40 x 0,05 mm) |
|
| Sensor
Technology |
Part Numbers |
pairs |
O.D. inches |
O.D. mm |
Part Numbers |
pairs |
O.D. inches |
O.D. mm |
|
| Computers |
244-0000-803 |
3 |
0.19 |
4.9 |
244-0000-812 |
12 |
0.33 |
8.3 |
|
| Measurement
devices |
244-0000-804 |
4 |
0.20 |
5.1 |
244-0000-818 |
18 |
0.37 |
9.3 |
|
| Control
devices |
244-0000-806 |
6 |
0.24 |
6.2 |
|
|
|
|
|
| Whenever
electrical interference |
244-0000-808 |
8 |
0.26 |
6.7 |
|
|
|
|
|
| distorts
signal transmission. |
24AWG (0,20 mm²) Stranding: VDE
0295, class 6 (102 x 0,05 mm) |
|
| Specifications: |
Part Numbers |
pairs |
O.D. inches |
O.D. mm |
Part Numbers |
pairs |
O.D. inches |
O.D. mm |
|
| According to VDE |
244-0002-002 |
2 |
0.24 |
6.0 |
244-0002-012 |
12 |
0.41 |
10.3 |
|
| # 0812 |
244-0002-003 |
3 |
0.26 |
6.6 |
244-0002-016 |
16 |
0.49 |
12.5 |
|
| |
244-0002-004 |
4 |
0.28 |
7.1 |
244-0002-018 |
18 |
0.51 |
13.0 |
|
| Construction: |
244-0002-005 |
5 |
0.31 |
7.9 |
244-0002-020 |
20 |
0.55 |
13.9 |
|
| Conductors: |
244-0002-006 |
6 |
0.34 |
8.5 |
244-0002-024 |
24 |
0.58 |
14.8 |
|
| very fine
bare copper strands |
244-0002-007 |
7 |
0.35 |
8.9 |
244-0002-032 |
32 |
0.65 |
16.6 |
|
| acc. to VDE
0295, class 6, with |
244-0002-008 |
8 |
0.37 |
9.3 |
|
|
|
|
|
| PVC
insulation |
244-0002-010 |
10 |
0.39 |
9.9 |
|
|
|
|
|
| Color code: |
|
|
|
|
|
|
|
|
|
| acc. to DIN
47100 |
|
|
|
|
|
|
|
|
|
| see color
code table |
|
|
|
|
|
|
|
|
|
| Stranding: |
|
|
|
|
|
|
|
|
|
| cores twisted
in pairs, pairs |
|
|
|
|
|
|
|
|
|
| twisted in
layers, braided screen |
|
|
|
|
|
|
|
|
|
| with drain
wire |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Jacket: |
|
|
|
|
|
|
|
|
|
| PVC jacket
gray, |
|
|
|
|
|
|
|
|
|
| self-extinguishing
and flame |
|
|
|
|
|
|
|
|
|
| retardant. |
|
|
|
|
|
|
|
|
|
| Technical
Data: |
|
|
|
|
|
|
|
|
|
| Rated
voltage: |
|
|
|
|
|
|
|
|
|
| 100 Volt
(0.08mm) |
|
|
|
|
|
|
|
|
|
| 250 Volt
(0.20mm) |
|
|
|
|
|
|
|
|
|
| Test voltage: |
|
|
|
|
|
|
|
|
|
| 800/1200 Volt |
|
|
|
|
|
|
|
|
|
| Bending
radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x
diameter |
|
|
|
|
|
|
|
|
|
| flexible
app.: 7.5 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
|
|
|
| fixed: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|