Silicone - Control - Cable - SiHF - 610 - UL
 
               
 
 
       
           
           
with filler if necessary Heat resistant          
Applications: 20AWG (0,50 mm²)  Stranding: VDE 0295, class 5  (16 x 0,20 mm)
High temperature areas Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Exposing to UV light 610-20-02 2 0.21 5.4 610-20-05 5 0.29 7.3
Steel mills, Glass factories 610-20-03 3 0.23 5.9        
Baking equipment, burners 610-20-04 4 0.25 6.4        
Heating and Lighting systems 19AWG (0,75 mm²)  Stranding: VDE 0295, class 5  (24 x 0,20 mm)
Salt water Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Specifications: 610-19-02 2 0.25 6.3 610-19-06 6 0.36 9.1
According to VDE  610-19-03 3 0.26 6.7 610-19-07 7 0.36 9.1
0250, 0282 610-19-04 4 0.30 7.5        
UL-style: 3512 610-19-05 5 0.33 8.4        
Construction: 18AWG (1,00 mm²)  Stranding: VDE 0295, class 5  (32 x 0,20 mm)
Conductors: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
tinned copper strands acc. to 610-18-02 2 0.26 6.7 610-18-06 6 0.38 9.6
VDE 0295, class 5, with  610-18-03 3 0.29 7.3 610-18-07 7 0.38 9.6
silicone insulation 610-18-04 4 0.31 7.9        
Color code: 610-18-05 5 0.35 8.9        
acc. to VDE 0293 16AWG (1,50 mm²)  Stranding: VDE 0295, class 5  (30 x 0,25 mm)
2 wires: bk,bl Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
3 wires: gn/yell,bk,bl 610-16-02 2 0.30 7.6 610-16-12 12 0.54 13.6
4 wires: gn/yell,bk,bl,bn 610-16-03 3 0.32 8.1 610-16-16 16 0.64 16.2
5 wires: gn/yell,bk,bl,bn,bk 610-16-04 4 0.35 8.8 610-16-18 18 0.67 17.0
6 wires and up with numbers 610-16-05 5 0.38 9.6 610-16-20 20 0.70 17.8
plus green/yellow 610-16-06 6 0.41 10.4 610-16-24 24 0.77 19.5
Stranding: 610-16-07 7 0.41 10.4        
cores twisted in layers 610-16-08 8 0.46 11.7        
Jacket: 14AWG (2,50 mm²)  Stranding: VDE 0295, class 5  (50 x 0,25 mm)
Silicone jacket, reddish brown, Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
halogen free, flame retardant,  610-14-02 2 0.37 9.3 610-14-06 6 0.50 12.7
UV resistant, Oil resistant 610-14-03 3 0.39 9.8 610-14-07 7 0.50 12.7
Technical Data: 610-14-04 4 0.42 10.7 610-14-12 12 0.67 17.1
Rated voltage: 610-14-05 5 0.46 11.7        
600 Volt 12AWG (4,00 mm²)  Stranding: VDE 0295, class 5  (56 x 0,30 mm)2
Test voltage: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
3,000 Volt 610-12-02 2 0.43 10.8 610-12-06 6 0.63 16.1
Bending radius: 610-12-03 3 0.45 11.5 610-12-07 7 0.63 16.1
fixed: 10 x diameter 610-12-04 4 0.52 13.1        
flexible app.: 15 x diameter 610-12-05 5 0.57 14.4        
Temperature range:                
fixed:  -65°F to 356°F                 
flex.:   -65°F to 356°F