| Hydro - N - Power - Cable - 722 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
|
|
|
| Applications: |
17AWG (1,00 mm²) Stranding: VDE
0295, class 5 (32 x 0,20 mm) |
|
| Suction pumps
(800 ft. deep) |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Electical
Equipments |
722-0010-03 |
3 |
0.39 |
9.8 |
|
|
|
|
|
| Machines,
Motors |
722-0010-04 |
4 |
0.44 |
11.0 |
|
|
|
|
|
| Hand-tools |
16AWG (1,50 mm²) Stranding: VDE
0295, class 5 (30 x 0,25 mm) |
|
| Wet and humid
areas |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Waste water
areas |
722-0015-03 |
3 |
0.41 |
10.5 |
|
|
|
|
|
| Specifications: |
722-0015-04 |
4 |
0.44 |
11.2 |
|
|
|
|
|
| According to
VDE 0282 |
14AWG (2,50 mm²) Stranding: VDE
0295, class 5 (50 x 0,25 mm) |
|
| |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Construction: |
722-0025-03 |
3 |
0.47 |
11.8 |
|
|
|
|
|
| Conductors: |
722-0025-04 |
4 |
0.51 |
12.9 |
|
|
|
|
|
| bare copper
strands acc. to |
12AWG (4,00 mm²) Stranding: VDE
0295, class 5 (56 x 0,30 mm) |
|
| VDE 0295, class 5, with |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| synthetic
rubber insulation |
722-0040-03 |
3 |
0.54 |
13.6 |
|
|
|
|
|
| |
722-0040-04 |
4 |
0.59 |
15.0 |
|
|
|
|
|
| Color code: |
10AWG (6,00 mm²) Stranding: VDE
0295, class 5 (84 x 0,30 mm) |
|
| acc. to VDE
0293 |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| 2 wires:
bk,bl |
722-0060-03 |
3 |
0.59 |
15.0 |
|
|
|
|
|
| 3 wires:
gn/yell,bk,bl |
722-0060-04 |
4 |
0.65 |
16.5 |
|
|
|
|
|
| 4 wires:
gn/yell,bk,bl,bn |
8AWG (10,00 mm²) Stranding:
VDE 0295, class 5 (80 x 0,40 mm) |
|
| 5 wires:
gn/yell,bk,bl,bn,bk |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| |
722-0100-03 |
3 |
0.87 |
22.0 |
|
|
|
|
|
| Stranding: |
722-0100-04 |
4 |
0.92 |
23.2 |
|
|
|
|
|
| cores twisted
in layers |
6AWG (16,00 mm²) Stranding:
VDE 0295, class 5 (128 x 0,40 mm) |
|
| Jacket: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
|
| Heavy duty, blue, synthetic |
722-0160-03 |
3 |
1.02 |
25.8 |
|
|
|
|
|
| rubber, flame retardant |
722-0160-04 |
4 |
1.10 |
27.8 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Technical
Data: |
|
|
|
|
|
|
|
|
|
| Rated
voltage: |
|
|
|
|
|
|
|
|
|
| 450/750 Volt |
|
|
|
|
|
|
|
|
|
| Test voltage: |
|
|
|
|
|
|
|
|
|
| 2,500 Volt |
|
|
|
|
|
|
|
|
|
| Bending
radius: |
|
|
|
|
|
|
|
|
|
| fixed: 7.5 x
diameter |
|
|
|
|
|
|
|
|
|
| flexible
app.: 12 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
|
|
|
| fixed: -49°F to 140°F |
|
|
|
|
|
|
|
|
|
| flex.: -13°F to 140°F |
|
|
|
|
|
|
|
|
|
| Inside water:
up to 104°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|