| CC-Schleppflex® PVC-570 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
|
|
|
|
|
|
|
| Applications: |
20AWG (0,50 mm²) Stranding: VDE
0295, class 6 (28 x 0,15 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Cooling liqid
resistant |
570-20-03 |
3 |
0.26 |
6.5 |
570-20-12 |
12 |
0.46 |
11.5 |
|
| UV resistant,
Oil resistant |
570-20-04 |
4 |
0.29 |
7.4 |
570-20-18 |
18 |
0.53 |
13.3 |
|
| Control
devices |
570-20-05 |
5 |
0.32 |
8.1 |
570-20-25 |
25 |
0.64 |
16.3 |
|
| Damp and wet
areas |
570-20-07 |
7 |
0.37 |
9.4 |
|
|
|
|
|
| Moving devices |
19AWG (0,75 mm²) Stranding: VDE
0295, class 6 (42 x 0,15 mm) |
|
| Specifications: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| According to VDE |
570-19-02 |
2 |
0.27 |
6.9 |
570-19-12 |
12 |
0.48 |
12.2 |
|
| 0245, 0281,
UL 2587 |
570-19-03 |
3 |
0.29 |
7.2 |
570-19-16 |
16 |
0.55 |
14.0 |
|
| CSA: AMW I
A/B, II A.B FT1 |
570-19-04 |
4 |
0.32 |
8.0 |
570-19-18 |
18 |
0.59 |
14.9 |
|
| Construction: |
570-19-05 |
5 |
0.34 |
8.6 |
570-19-25 |
25 |
0.70 |
17.7 |
|
| Conductors: |
570-19-07 |
7 |
0.41 |
10.4 |
|
|
|
|
|
| Fine bare
copper strands acc. |
18AWG (1,00 mm²) Stranding: VDE
0295, class 6 (56 x 0,15 mm) |
|
| to VDE 0295, class 6, with |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| PVC
insulation |
570-18-02 |
2 |
0.30 |
7.5 |
570-18-16 |
16 |
0.57 |
14.5 |
|
| Color code: |
570-18-03 |
3 |
0.30 |
7.6 |
570-18-18 |
18 |
0.62 |
15.8 |
|
| black
conductors with white |
570-18-04 |
4 |
0.33 |
8.2 |
570-18-25 |
25 |
0.75 |
18.9 |
|
| consec.
numbers, cables with |
570-18-05 |
5 |
0.25 |
8.9 |
570-18-34 |
34 |
0.84 |
21.3 |
|
| three or more
conductors |
570-18-07 |
7 |
0.43 |
10.8 |
570-18-41 |
41 |
0.95 |
24.1 |
|
| with green/yellow ground |
570-18-12 |
12 |
0.54 |
13.6 |
570-18-50 |
50 |
0.99 |
25.1 |
|
| wire in the
outer layer |
16AWG (1,50 mm²) Stranding: VDE
0295, class 6 (84 x 0,15 mm) |
|
| Stranding: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| cores twisted
in layers |
570-16-03 |
3 |
0.33 |
8.2 |
570-16-18 |
18 |
0.66 |
16.8 |
|
| with very
short lay lengths |
570-16-04 |
4 |
0.36 |
9.0 |
570-16-25 |
25 |
0.82 |
20.8 |
|
| and fleece
around cores |
570-16-05 |
5 |
0.40 |
10.0 |
570-16-34 |
34 |
0.92 |
23.3 |
|
| Jacket: |
570-16-07 |
7 |
0.47 |
11.9 |
570-16-42 |
42 |
1.04 |
26.5 |
|
| PVC jacket
black |
570-16-12 |
12 |
0.57 |
14.4 |
570-16-50 |
50 |
1.09 |
27.6 |
|
| flame
retardant and self- |
570-16-16 |
16 |
0.63 |
15.9 |
|
|
|
|
|
|
| extinguishing |
14AWG (2,50 mm²) Stranding: VDE
0295, class 6 (140 x 0,15 mm) |
|
| Technical
Data: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Rated voltage: |
570-14-03 |
3 |
0.42 |
10.5 |
570-14-07 |
7 |
0.60 |
15.1 |
|
| 600 Volt |
570-14-04 |
4 |
0.45 |
11.4 |
570-14-12 |
12 |
0.74 |
18.8 |
|
| Test voltage: |
570-14-05 |
5 |
0.49 |
12.5 |
|
|
|
|
|
| 4,000 Volt |
12AWG (4,00 mm²) Stranding: VDE
0295, class 6 (224 x 0,15 mm) |
|
| Bending
radius: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| fixed: 5 x
diameter |
570-12-03 |
3 |
0.45 |
11.4 |
570-12-05 |
5 |
0.56 |
14.3 |
|
| flexible
app.: 7.5 x diameter |
570-12-04 |
4 |
0.51 |
12.8 |
570-12-07 |
7 |
0.69 |
17.4 |
|
| Temperature
range: |
10AWG (6,00 mm²) Stranding: VDE
0295, class 6 (192 x 0,20 mm) |
|
| fixed: 23°F to 194°F |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| flex.: 23°F to 194°F |
570-10-04 |
4 |
0.56 |
14.3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|