| CC-Schleppflex® PVC-C-573 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
shielded |
|
|
|
|
|
|
| Applications: |
20AWG (0,50 mm²) Stranding: VDE
0295, class 6 (28 x 0,15 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Electical
Equipments |
573-0005-002 |
2 |
0.30 |
7.5 |
573-0005-025 |
25 |
0.65 |
16.4 |
|
| Sensor
technology |
573-0005-003 |
3 |
0.31 |
7.8 |
573-0005-030 |
30 |
0.69 |
17.4 |
|
| Control
devices |
573-0005-004 |
4 |
0.33 |
8.2 |
573-0005-034 |
34 |
0.74 |
18.6 |
|
| Whenever
electrical interference |
573-0005-005 |
5 |
0.37 |
9.3 |
573-0005-036 |
36 |
0.74 |
18.6 |
|
| distorts
signal transmission. |
573-0005-007 |
7 |
0.43 |
10.7 |
573-0005-042 |
42 |
0.78 |
19.7 |
|
| Specifications: |
573-0005-012 |
12 |
0.49 |
12.4 |
573-0005-050 |
50 |
0.86 |
21.7 |
|
| According to VDE |
573-0005-014 |
14 |
0.51 |
12.8 |
573-0005-061 |
61 |
0.94 |
23.8 |
|
| 0245, 0281 |
573-0005-016 |
16 |
0.54 |
13.6 |
|
|
|
|
|
| Construction: |
573-0005-018 |
18 |
0.57 |
14.4 |
|
|
|
|
|
| Conductors: |
18AWG (0,75 mm²) Stranding: VDE
0295, class 6 (42 x 0,15 mm) |
|
| Fine bare
copper strands acc. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| to VDE 0295, class 6, with |
573-0007-002 |
2 |
0.32 |
8.1 |
573-0007-018 |
18 |
0.63 |
15.9 |
|
| PVC
insulation |
573-0007-003 |
3 |
0.33 |
8.4 |
573-0007-025 |
25 |
0.74 |
18.6 |
|
| Color code: |
573-0007-004 |
4 |
0.37 |
9.4 |
573-0007-030 |
30 |
0.79 |
19.9 |
|
| black
conductors with white |
573-0007-005 |
5 |
0.41 |
10.3 |
573-0007-034 |
34 |
0.83 |
21.0 |
|
| consec.
numbers, cables with |
573-0007-007 |
7 |
0.48 |
12.1 |
573-0007-036 |
36 |
0.83 |
21.0 |
|
| three or more
conductors |
573-0007-012 |
12 |
0.54 |
13.6 |
573-0007-042 |
42 |
0.88 |
22.4 |
|
| with
green/yellow ground wire |
573-0007-014 |
14 |
0.55 |
13.9 |
573-0007-050 |
50 |
0.93 |
23.7 |
|
| in the outer
layer |
573-0007-016 |
16 |
0.59 |
15.0 |
573-0007-061 |
61 |
1.05 |
26.7 |
|
| Stranding: |
17AWG (1,00 mm²) Stranding: VDE
0295, class 6 (56 x 0,15 mm) |
|
| cores twisted
in layers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| with very
short lay lengths |
573-0010-002 |
2 |
0.39 |
9.9 |
573-0010-018 |
18 |
0.71 |
17.9 |
|
| fleece around
cores, and inner |
573-0010-003 |
3 |
0.40 |
10.2 |
573-0010-025 |
25 |
0.83 |
21.0 |
|
| jacket gray
plus common shield |
573-0010-004 |
4 |
0.43 |
10.9 |
573-0010-034 |
34 |
0.94 |
23.8 |
|
| Jacket: |
573-0010-005 |
5 |
0.46 |
11.7 |
573-0010-041 |
41 |
1.03 |
26.1 |
|
|
| Outer jacket
gray, flame retardant |
573-0010-007 |
7 |
0.53 |
13.5 |
573-0010-050 |
50 |
1.10 |
27.9 |
|
| and
self-extinguishing, common |
573-0010-012 |
12 |
0.61 |
15.5 |
573-0010-065 |
65 |
1.27 |
32.3 |
|
| braided
shield between jackets |
573-0010-016 |
16 |
0.68 |
17.1 |
|
|
|
|
|
| Technical
Data: |
16AWG (1,50 mm²) Stranding: VDE
0295, class 6 (84 x 0,15 mm) |
|
| Rated
voltage: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| 300/500 Volt |
573-0015-002 |
2 |
0.41 |
10.3 |
|
|
|
|
|
| Test voltage: |
573-0015-003 |
3 |
0.43 |
10.7 |
|
|
|
|
|
| 3,000 volt |
573-0015-004 |
4 |
0.45 |
11.4 |
|
|
|
|
|
| Bending
radius: |
573-0015-005 |
5 |
0.49 |
12.3 |
|
|
|
|
|
| fixed: 5 x
diameter |
573-0015-007 |
7 |
0.57 |
14.5 |
|
|
|
|
|
| flexible
app.: 7.5 x diameter |
573-0015-012 |
12 |
0.65 |
16.3 |
|
|
|
|
|
| Temperature
range: |
573-0015-016 |
16 |
0.76 |
19.3 |
|
|
|
|
|
| fixed: 23°F to 158°F |
573-0015-018 |
18 |
0.80 |
20.3 |
|
|
|
|
|
| flex.: 23°F to 158°F |
573-0015-025 |
25 |
0.92 |
23.2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|