| CC-Schleppflex® PVC-C-573 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
shielded |
|
|
|
|
|
|
| Applications: |
14AWG (2,50 mm²) Stranding: VDE
0295, class 6 (140 x 0,15 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Electical
Equipments |
573-0025-003 |
3 |
0.51 |
12.8 |
573-0025-007 |
7 |
0.70 |
17.6 |
|
| Sensor
technology |
573-0025-004 |
4 |
0.54 |
13.7 |
|
|
|
|
|
| Control
devices |
573-0025-005 |
5 |
0.60 |
15.2 |
|
|
|
|
|
| Whenever
electrical interference |
12AWG (4,00 mm²) Stranding: VDE
0295, class 6 (224 x 0,15 mm) |
|
| distorts
signal transmission. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Specifications: |
573-0040-003 |
3 |
0.61 |
15.5 |
573-0040-007 |
7 |
0.83 |
21.1 |
|
| According to VDE |
573-0040-004 |
4 |
0.64 |
16.6 |
|
|
|
|
|
| 0245, 0281 |
573-0040-005 |
5 |
0.71 |
17.9 |
|
|
|
|
|
| Construction: |
10AWG (6,00 mm²) Stranding: VDE
0295, class 6 (192 x 0,20 mm) |
|
| Conductors: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Fine bare
copper strands acc. |
573-0060-004 |
4 |
0.75 |
18.9 |
573-0060-007 |
7 |
0.94 |
23.7 |
|
| to VDE 0295, class 6, with |
573-0060-005 |
5 |
0.81 |
20.5 |
|
|
|
|
|
| PVC insulation |
8AWG (10,00 mm²) Stranding:
VDE 0295, class 6 (320 x 0,20 mm) |
|
| Color code: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| black
conductors with white |
573-0100-004 |
4 |
0.90 |
22.7 |
|
|
|
|
|
| consec.
numbers, cables with |
573-0100-005 |
5 |
0.97 |
24.5 |
|
|
|
|
|
| three or more
conductors |
6AWG (16,00 mm²) Stranding:
VDE 0295, class 6 (512 x 0,20 mm) |
|
| with
green/yellow ground wire |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| in the outer
layer |
573-0160-004 |
4 |
1.00 |
25.4 |
|
|
|
|
|
| Stranding: |
573-0160-005 |
5 |
1.10 |
28.0 |
|
|
|
|
|
| cores twisted
in layers |
|
|
|
|
|
|
|
|
|
| with very
short lay lengths |
|
|
|
|
|
|
|
|
|
| fleece around
cores, and inner |
|
|
|
|
|
|
|
|
|
| jacket gray
plus common shield |
|
|
|
|
|
|
|
|
|
| Jacket: |
|
|
|
|
|
|
|
|
|
|
| Outer jacket
gray, flame retardant |
|
|
|
|
|
|
|
|
|
| and
self-extinguishing, common |
|
|
|
|
|
|
|
|
|
| braided
shield between jackets |
|
|
|
|
|
|
|
|
|
| Technical
Data: |
|
|
|
|
|
|
|
|
|
| Rated
voltage: |
|
|
|
|
|
|
|
|
|
| 300/500 Volt |
|
|
|
|
|
|
|
|
|
| Test voltage: |
|
|
|
|
|
|
|
|
|
| 3,000 volt |
|
|
|
|
|
|
|
|
|
| Bending
radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x
diameter |
|
|
|
|
|
|
|
|
|
| flexible
app.: 7.5 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
|
|
|
| fixed: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|