| CC-Schleppflex® PVC-C-573 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
shielded |
|
|
|
|
|
|
| Applications: |
14AWG (2,50 mm²) Stranding: VDE
0295, class 6 (140 x 0,15 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Electical
Equipments |
573-14-03 |
3 |
0.46 |
11.5 |
573-14-12 |
12 |
0.79 |
20.0 |
|
| UV, Oil and
Cooling liquid resistant |
573-14-04 |
4 |
0.50 |
12.7 |
|
|
|
|
|
| Control
devices |
573-14-05 |
5 |
0.55 |
13.9 |
|
|
|
|
|
| Whenever
electrical interference |
573-14-07 |
7 |
0.66 |
16.8 |
|
|
|
|
|
| distorts
signal transmission. |
12AWG (4,00 mm²) Stranding: VDE
0295, class 6 (224 x 0,15 mm) |
|
| Specifications: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| According to
VDE 0245/0281 |
573-12-03 |
3 |
0.52 |
13.0 |
573-12-07 |
7 |
0.77 |
19.5 |
|
| UL 2587/CSA
AWM I A/B, II A.B FT1 |
573-12-04 |
4 |
0.59 |
14.8 |
|
|
|
|
|
| Construction: |
573-12-05 |
5 |
0.65 |
16.4 |
|
|
|
|
|
| Conductors: |
10AWG (6,00 mm²) Stranding: VDE
0295, class 6 (192 x 0,20 mm) |
|
| Fine bare
copper strands acc. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| to VDE 0295, class 6, with |
573-10-04 |
4 |
0.67 |
16.9 |
|
|
|
|
|
| PVC insulation |
8AWG (10,00 mm²) Stranding:
VDE 0295, class 6 (320 x 0,20 mm) |
|
| Color code: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| black
conductors with white |
573-08-04 |
4 |
0.84 |
21.3 |
|
|
|
|
|
| consec.
numbers, cables with |
6AWG (16,00 mm²) Stranding:
VDE 0295, class 6 (512 x 0,20 mm) |
|
| three or more
conductors |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| with
green/yellow ground wire |
573-06-04 |
4 |
1.02 |
25.9 |
|
|
|
|
|
| in the outer
layer |
|
|
|
|
|
|
|
|
|
| Stranding: |
|
|
|
|
|
|
|
|
|
| cores twisted
in layers |
|
|
|
|
|
|
|
|
|
| with very
short lay lengths |
|
|
|
|
|
|
|
|
|
| fleece around
cores, and inner |
|
|
|
|
|
|
|
|
|
| jacket gray
plus common shield |
|
|
|
|
|
|
|
|
|
| Jacket: |
|
|
|
|
|
|
|
|
|
|
| Outer jacket
black, flame retardant |
|
|
|
|
|
|
|
|
|
| and
self-extinguishing, common |
|
|
|
|
|
|
|
|
|
| braided
shield between jackets |
|
|
|
|
|
|
|
|
|
| Technical
Data: |
|
|
|
|
|
|
|
|
|
| Rated
voltage: |
|
|
|
|
|
|
|
|
|
| 600 Volt |
|
|
|
|
|
|
|
|
|
| Test voltage: |
|
|
|
|
|
|
|
|
|
| 4,000 volt |
|
|
|
|
|
|
|
|
|
| Bending
radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x
diameter |
|
|
|
|
|
|
|
|
|
| flexible
app.: 7.5 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
|
|
|
| fixed: 23°F to 194°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 194°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|