| CC-Schleppflex® PUR-575 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
|
|
|
|
|
|
|
| Applications: |
20AWG (0,50 mm²) Stranding: VDE
0295, class 6 (28 x 0,15 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Electical
Equipments |
575-0005-003 |
3 |
0.26 |
6.6 |
575-0005-018 |
18 |
0.48 |
12.2 |
|
| Harsh
environment |
575-0005-004 |
4 |
0.28 |
7.0 |
575-0005-025 |
25 |
0.62 |
15.8 |
|
| Control
devices |
575-0005-005 |
5 |
0.29 |
7.4 |
575-0005-034 |
34 |
0.68 |
17.1 |
|
| Damp and wet
areas |
575-0005-007 |
7 |
0.34 |
8.6 |
|
|
|
|
|
| Moving
devices |
575-0005-012 |
12 |
0.40 |
10.1 |
|
|
|
|
|
| Specifications: |
18AWG (0,75 mm²) Stranding: VDE
0295, class 6 (42 x 0,15 mm) |
|
| According to VDE |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| 0245, 0281 |
575-0007-003 |
3 |
0.27 |
6.8 |
575-0007-016 |
16 |
0.50 |
12.6 |
|
| Construction: |
575-0007-004 |
4 |
0.29 |
7.4 |
575-0007-018 |
18 |
0.53 |
13.5 |
|
| Conductors: |
575-0007-005 |
5 |
0.32 |
8.0 |
575-0007-025 |
25 |
0.66 |
16.7 |
|
| Fine bare
copper strands acc. |
575-0007-007 |
7 |
0.38 |
9.5 |
575-0007-034 |
34 |
0.77 |
19.4 |
|
| to VDE 0295, class 6, with |
575-0007-012 |
12 |
0.45 |
11.3 |
|
|
|
|
|
| PVC insulation |
17AWG (1,00 mm²) Stranding: VDE
0295, class 6 (56 x 0,15 mm) |
|
| Color code: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| black
conductors with white |
575-0010-003 |
3 |
0.29 |
7.2 |
575-0010-025 |
25 |
0.71 |
18.0 |
|
| consec.
numbers, cables with |
575-0010-004 |
4 |
0.31 |
7.8 |
575-0010-034 |
34 |
0.78 |
19.8 |
|
| three or more
conductors |
575-0010-005 |
5 |
0.34 |
8.5 |
575-0010-041 |
41 |
0.85 |
21.5 |
|
| with green/yellow ground |
575-0010-007 |
7 |
0.41 |
10.2 |
575-0010-050 |
50 |
0.91 |
23.1 |
|
| wire in the
outer layer |
575-0010-012 |
12 |
0.48 |
12.2 |
575-0010-065 |
65 |
1.04 |
26.5 |
|
| Stranding: |
575-0010-016 |
16 |
0.55 |
13.8 |
|
|
|
|
|
| cores twisted
in layers |
575-0010-018 |
18 |
0.58 |
14.7 |
|
|
|
|
|
| with very
short lay lengths |
16AWG (1,50 mm²) Stranding: VDE
0295, class 6 (84 x 0,15 mm) |
|
| and fleece
around cores |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Jacket: |
575-0015-003 |
3 |
0.32 |
8.0 |
575-0015-025 |
25 |
0.80 |
20.2 |
|
| PUR jacket
gray |
575-0015-004 |
4 |
0.34 |
8.7 |
575-0015-034 |
34 |
0.86 |
21.9 |
|
| flame
retardant and self- |
575-0015-005 |
5 |
0.39 |
9.7 |
575-0015-042 |
42 |
0.94 |
23.8 |
|
| extinguishing,
resistant against |
575-0015-007 |
7 |
0.47 |
11.8 |
575-0015-050 |
50 |
1.02 |
26.0 |
|
|
| mineral oils,
hydrolysis, microbes |
575-0015-012 |
12 |
0.54 |
13.7 |
575-0015-061 |
61 |
1.19 |
30.2 |
|
| Technical
Data: |
575-0015-016 |
16 |
0.63 |
15.9 |
|
|
|
|
|
| Rated voltage: |
575-0015-018 |
18 |
0.65 |
16.5 |
|
|
|
|
|
| 300/500 Volt |
14AWG (2,50 mm²) Stranding: VDE
0295, class 6 (140 x 0,15 mm) |
|
| Test voltage: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| 3,000 Volt |
575-0025-003 |
3 |
0.38 |
9.6 |
575-0025-014 |
14 |
0.72 |
18.1 |
|
| Bending
radius: |
575-0025-004 |
4 |
0.42 |
10.7 |
575-0025-018 |
18 |
0.85 |
21.5 |
|
| fixed: 5 x
diameter |
575-0025-005 |
5 |
0.48 |
12.0 |
575-0025-025 |
25 |
1.05 |
26.6 |
|
| flexible
app.: 7.5 x diameter |
575-0025-007 |
7 |
0.57 |
14.4 |
|
|
|
|
|
| Temperature
range: |
575-0025-012 |
12 |
0.67 |
16.9 |
|
|
|
|
|
| fixed: 23°F to 158°F |
|
|
|
|
|
|
|
|
|