| CC-Schleppflex® PUR-575-UL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
|
|
|
|
|
|
|
| Applications: |
20AWG (0,50 mm²) Stranding: VDE
0295, class 6 (28 x 0,15 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Electical
Equipments |
575-20-03 |
3 |
0.28 |
7.1 |
575-20-18 |
18 |
0.54 |
13.6 |
|
| Harsh
environment |
575-20-04 |
4 |
0.32 |
8.1 |
575-20-25 |
25 |
0.65 |
16.3 |
|
| Control
devices |
575-20-05 |
5 |
0.33 |
8.4 |
575-20-34 |
34 |
0.75 |
19.0 |
|
| Moving
devices |
575-20-07 |
7 |
0.39 |
9.7 |
|
|
|
|
|
| Specifications: |
575-20-12 |
12 |
0.46 |
11.6 |
|
|
|
|
|
| According to VDE 0245/0281 |
19AWG (0,75 mm²) Stranding: VDE
0295, class 6 (42 x 0,15 mm) |
|
| UL style
10012/20234 |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| CSA AWM 1
A/B, II A/B FT 1 |
575-19-03 |
3 |
0.28 |
6.9 |
575-19-16 |
16 |
0.54 |
13.6 |
|
| Construction: |
575-19-04 |
4 |
0.30 |
7.5 |
575-19-18 |
18 |
0.56 |
14.1 |
|
| Conductors: |
575-19-05 |
5 |
0.33 |
8.2 |
575-19-25 |
25 |
0.68 |
17.3 |
|
| Fine bare
copper strands acc. |
575-19-07 |
7 |
0.40 |
10.1 |
575-19-34 |
34 |
0.78 |
19.7 |
|
| to VDE 0295, class 6, with |
575-19-12 |
12 |
0.51 |
12.9 |
|
|
|
|
|
| PVC insulation |
18AWG (1.00 mm²) Stranding: VDE
0295, class 6 (56 x 0,15 mm) |
|
| Color code: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| black
conductors with white |
575-18-03 |
3 |
0.28 |
7.1 |
575-18-16 |
16 |
0.57 |
14.4 |
|
| consec.
numbers, cables with |
575-18-04 |
4 |
0.30 |
7.7 |
575-18-18 |
18 |
0.58 |
14.6 |
|
| three or more
conductors |
575-18-05 |
5 |
0.34 |
8.5 |
575-18-25 |
25 |
0.71 |
18.0 |
|
| with green/yellow ground |
575-18-07 |
7 |
0.41 |
10.4 |
575-18-34 |
34 |
0.81 |
20.4 |
|
| wire in the
outer layer |
575-18-12 |
12 |
0.49 |
12.5 |
575-18-41 |
41 |
0.99 |
25.0 |
|
| Stranding: |
16AWG (1.50 mm²) Stranding: VDE
0295, class 6 (84 x 0,15 mm) |
|
| cores twisted
in layers |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| with very
short lay lengths |
575-16-03 |
3 |
0.34 |
8.5 |
575-16-18 |
18 |
0.67 |
17.0 |
|
| and fleece
around cores |
575-16-04 |
4 |
0.37 |
9.3 |
575-16-25 |
25 |
0.82 |
20.8 |
|
| Jacket: |
575-16-05 |
5 |
0.40 |
10.1 |
575-16-34 |
34 |
0.89 |
22.6 |
|
| PUR jacket
gray |
575-16-07 |
7 |
0.47 |
11.9 |
575-16-50 |
50 |
1.12 |
28.4 |
|
| flame
retardant and self- |
575-16-12 |
12 |
0.56 |
14.3 |
557-16-61 |
61 |
1.18 |
30.0 |
|
| extinguishing,
resistant against |
575-16-16 |
16 |
0.64 |
16.2 |
|
|
|
|
|
|
| mineral oils,
hydrolysis, microbes |
14AWG (2.50 mm²) Stranding: VDE
0295, class 6 (140 x 0,15 mm) |
|
| Technical
Data: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Rated voltage: |
575-14-03 |
3 |
0.41 |
10.2 |
575-14-07 |
7 |
0.57 |
14.5 |
|
| 600 Volt |
575-14-04 |
4 |
0.44 |
11.1 |
575-14-12 |
12 |
0.71 |
18.0 |
|
| Test voltage: |
575-14-05 |
5 |
0.48 |
12.1 |
|
|
|
|
|
| 4,000 Volt |
12AWG (4.00 mm²) Stranding: VDE
0295, class 6 (224 x 0,15 mm) |
|
| Bending
radius: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| fixed: 5 x
diameter |
575-12-04 |
4 |
0.53 |
13.4 |
575-12-07 |
7 |
0.73 |
18.5 |
|
| flexible
app.: 7.5 x diameter |
575-12-05 |
5 |
0.59 |
14.8 |
|
|
|
|
|
| Temperature
range: |
10AWG (6.00 mm²) Stranding: VDE
0295, class 6 (192 x 0,20 mm) |
|
| fixed: 23°F to 176°F |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| flex.: 23°F to 176°F |
575-10-04 |
4 |
0.60 |
15.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|