| CC-Schleppflex® PUR-C-576 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
shielded |
|
|
|
|
|
|
| Applications: |
20AWG (0.50 mm²) Stranding: VDE
0295, class 6 (28 x 0.15 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Sensor
technology |
576-0005-003 |
3 |
0.31 |
7.8 |
576-0005-025 |
25 |
0.64 |
16.1 |
|
| Control
devices |
576-0005-004 |
4 |
0.31 |
7.9 |
|
|
|
|
|
| Damp and wet
areas |
576-0005-005 |
5 |
0.33 |
8.4 |
|
|
|
|
|
| Whenever
elecrical interference |
576-0005-007 |
7 |
0.39 |
9.8 |
|
|
|
|
|
| distorts
signal transmission. |
576-0005-012 |
12 |
0.45 |
11.3 |
|
|
|
|
|
| Specifications: |
576-0005-018 |
18 |
0.53 |
13.4 |
|
|
|
|
|
| According to
VDE 0281, 0245 |
18AWG (0.75 mm²) Stranding: VDE
0295, class 6 (42 x 0.15 mm) |
|
| Construction: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Conductors: |
576-0007-003 |
3 |
0.31 |
7.8 |
576-0007-018 |
18 |
0.59 |
14.9 |
|
| Fine bare
copper strands acc. |
576-0007-004 |
4 |
0.33 |
8.4 |
576-0007-025 |
25 |
0.71 |
18.0 |
|
| to VDE 0295, class 6, with |
576-0007-005 |
5 |
0.36 |
9.0 |
576-0007-034 |
34 |
0.87 |
22.0 |
|
| PVC
insulation |
576-0007-007 |
7 |
0.42 |
10.7 |
|
|
|
|
|
| Color code: |
576-0007-012 |
12 |
0.49 |
12.4 |
|
|
|
|
|
| black cond.
with white consec. |
576-0007-014 |
14 |
0.55 |
14.0 |
|
|
|
|
|
| numbers,
cables with three or |
17AWG (1.00 mm²) Stranding: VDE
0295, class 6 (56 x 0.15 mm) |
|
| more cond.
with yellow/green |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| ground wire
in the outer layer |
576-0010-003 |
3 |
0.33 |
8.2 |
576-0010-025 |
25 |
0.77 |
19.5 |
|
| Stranding: |
576-0010-004 |
4 |
0.35 |
8.9 |
576-0010-034 |
34 |
0.93 |
23.5 |
|
| cores twisted
in layers with |
576-0010-005 |
5 |
0.39 |
9.8 |
576-0010-041 |
41 |
1.00 |
25.4 |
|
| very short
lay lengths and fleece |
576-0010-007 |
7 |
0.45 |
11.4 |
576-0010-050 |
50 |
1.06 |
27.1 |
|
| around cores,
plus common |
576-0010-012 |
12 |
0.53 |
13.4 |
576-0010-065 |
65 |
1.24 |
31.4 |
|
| shield and
inner jacket PVC |
576-0010-016 |
16 |
0.60 |
15.2 |
|
|
|
|
|
| Jacket: |
576-0010-018 |
18 |
0.64 |
16.1 |
|
|
|
|
|
| outer PUR
jacket, gray |
16AWG (1.50 mm²) Stranding: VDE
0295, class 6 (84 x 0.15 mm) |
|
| flame
retardant and self- |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
|
| extinguishing,
resistant against |
576-0015-003 |
3 |
0.36 |
9.0 |
576-0015-025 |
25 |
0.86 |
21.9 |
|
| minaral oils,
hydrolysis and |
576-0015-004 |
4 |
0.39 |
9.9 |
576-0015-034 |
34 |
1.08 |
27.5 |
|
| microbes |
576-0015-005 |
5 |
0.43 |
10.9 |
576-0015-042 |
42 |
1.17 |
29.8 |
|
| Technical
Data: |
576-0015-007 |
7 |
0.50 |
12.7 |
576-0015-050 |
50 |
1.27 |
32.3 |
|
| Rated
voltage: |
576-0015-012 |
12 |
0.60 |
15.1 |
|
|
|
|
|
| 300/500 Volt |
576-0015-016 |
16 |
0.66 |
16.8 |
|
|
|
|
|
| Test voltage: |
576-0015-018 |
18 |
0.70 |
17.8 |
|
|
|
|
|
| 3,000 Volt |
|
|
|
|
|
|
|
|
|
| Bending
radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x
diameter |
|
|
|
|
|
|
|
|
|
| flexible
app.: 7.5 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
|
|
|
| fixed: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|