| CC-Schleppflex® PUR-C-576 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
shielded |
|
|
|
|
|
|
| Applications: |
14AWG (2.50 mm²) Stranding: VDE
0295, class 6 (140 x 0.15 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Sensor
technology |
576-0025-003 |
3 |
0.43 |
10.8 |
576-0025-007 |
7 |
0.63 |
15.8 |
|
| Control
devices |
576-0025-004 |
4 |
0.47 |
11.8 |
576-0025-012 |
12 |
0.72 |
18.2 |
|
| Damp and wet
areas |
576-0025-005 |
5 |
0.52 |
13.2 |
|
|
|
|
|
| Whenever
elecrical interference |
12AWG (4.00 mm²) Stranding: VDE
0295, class 6 (224 x 0.15 mm) |
|
| distorts
signal transmission. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Specifications: |
576-0040-003 |
3 |
0.49 |
12.4 |
|
|
|
|
|
| According to
VDE 0281, 0245 |
576-0040-004 |
4 |
0.54 |
13.7 |
|
|
|
|
|
| Construction: |
576-0040-005 |
5 |
0.61 |
15.3 |
|
|
|
|
|
| Conductors: |
10AWG (6.00 mm²) Stranding: VDE
0295, class 6 (192 x 0.20 mm) |
|
| Fine bare
copper strands acc. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| to VDE 0295, class 6, with |
576-0060-004 |
4 |
0.64 |
16.1 |
|
|
|
|
|
| PVC
insulation |
576-0060-005 |
5 |
0.68 |
17.1 |
|
|
|
|
|
| Color code: |
8AWG (10.00 mm²) Stranding:
VDE 0295, class 6 (320 x 0.20 mm) |
|
| black cond.
with white consec. |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| numbers,
cables with three or |
576-0100-004 |
4 |
0.80 |
20.2 |
|
|
|
|
|
| more cond.
with yellow/green |
576-0100-005 |
5 |
0.88 |
22.2 |
|
|
|
|
|
| ground wire
in the outer layer |
6AWG (16.00 mm²) Stranding:
VDE 0295, class 6 (512 x 0.20 mm) |
|
| Stranding: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| cores twisted
in layers with |
576-0160-004 |
4 |
0.92 |
23.2 |
|
|
|
|
|
| very short
lay lengths and fleece |
576-0160-005 |
5 |
1.03 |
26.1 |
|
|
|
|
|
| around cores,
plus common |
|
|
|
|
|
|
|
|
|
| shield and
inner jacket PVC |
|
|
|
|
|
|
|
|
|
| Jacket: |
|
|
|
|
|
|
|
|
|
| outer PUR
jacket, gray |
|
|
|
|
|
|
|
|
|
| flame
retardant and self- |
|
|
|
|
|
|
|
|
|
|
| extinguishing,
resistant against |
|
|
|
|
|
|
|
|
|
| minaral oils,
hydrolysis and |
|
|
|
|
|
|
|
|
|
| microbes |
|
|
|
|
|
|
|
|
|
| Technical
Data: |
|
|
|
|
|
|
|
|
|
| Rated
voltage: |
|
|
|
|
|
|
|
|
|
| 300/500 Volt |
|
|
|
|
|
|
|
|
|
| Test voltage: |
|
|
|
|
|
|
|
|
|
| 3,000 Volt |
|
|
|
|
|
|
|
|
|
| Bending
radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x
diameter |
|
|
|
|
|
|
|
|
|
| flexible
app.: 7.5 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
|
|
|
| fixed: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 158°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|