| CC-Schleppflex® PUR-572 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Superflex |
|
halogen-free |
|
|
|
|
|
|
| Applications: |
16AWG (1,50 mm²) Stranding: VDE
0295, class 6 (84 x 0.15 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Electical
Equipments |
572-0015-002 |
2 |
0.26 |
6.5 |
572-0015-027 |
27 |
0.70 |
17.6 |
|
| Harsh
environment |
572-0015-003 |
3 |
0.28 |
7.1 |
572-0015-030 |
30 |
0.72 |
18.1 |
|
| Control
devices |
572-0015-004 |
4 |
0.31 |
7.7 |
572-0015-034 |
34 |
0.76 |
19.2 |
|
| Damp and wet
areas |
572-0015-005 |
5 |
0.33 |
8.3 |
572-0015-036 |
36 |
0.77 |
19.4 |
|
| Moving
devices |
572-0015-007 |
7 |
0.40 |
10.1 |
572-0015-042 |
42 |
0.84 |
21.2 |
|
| Specifications: |
572-0015-012 |
12 |
0.48 |
12.2 |
572-0015-050 |
50 |
1.07 |
27.2 |
|
| According to VDE |
572-0015-014 |
14 |
0.52 |
13.1 |
572-0015-061 |
61 |
1.18 |
30.0 |
|
| 0245, 0281 |
572-0015-018 |
18 |
0.56 |
14.3 |
572-0015-065 |
65 |
1.25 |
31.7 |
|
| Construction: |
572-0015-020 |
20 |
0.60 |
15.3 |
|
|
|
|
|
| Conductors: |
572-0015-025 |
25 |
0.68 |
17.3 |
|
|
|
|
|
| Fine bare
copper strands acc. |
14AWG (2.50 mm²) Stranding: VDE
0295, class 6 (140 x 0.15 mm) |
|
| to VDE 0295, class 6, with |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| TPE
insulation |
572-0025-003 |
3 |
0.33 |
8.4 |
572-0025-014 |
14 |
0.61 |
15.5 |
|
| Color code: |
572-0025-004 |
4 |
0.35 |
8.9 |
572-0025-018 |
18 |
0.68 |
17.2 |
|
| black
conductors with white |
572-0025-005 |
5 |
0.40 |
10.1 |
572-0025-025 |
25 |
0.83 |
21.1 |
|
| consec.
numbers, cables with |
572-0025-007 |
7 |
0.46 |
11.7 |
|
|
|
|
|
| three or more
conductors |
572-0025-012 |
12 |
0.56 |
14.2 |
|
|
|
|
|
| with green/yellow ground |
12AWG (4.00 mm²) Stranding: VDE
0295, class 6 (224 x 0.15 mm) |
|
| wire in the
outer layer |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Stranding: |
572-0040-003 |
3 |
0.41 |
10.2 |
572-0040-005 |
5 |
0.48 |
12.1 |
|
| cores twisted
in layers with very |
572-0040-004 |
4 |
0.44 |
11.1 |
572-0040-007 |
7 |
0.57 |
14.4 |
|
| short lay
lengths and fleece around |
10AWG (6.00 mm²) Stranding: VDE
0295, class 6 (192 x 0.20 mm) |
|
| cores,
bandage over each layer |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Jacket: |
572-0060-003 |
3 |
0.46 |
11.5 |
572-0060-005 |
5 |
0.55 |
13.9 |
|
| PUR jacket
gray |
572-0060-004 |
4 |
0.49 |
12.5 |
572-0060-007 |
7 |
0.66 |
16.6 |
|
| flame
retardant and self- |
8AWG (10.00 mm²) Stranding:
VDE 0295, class 6 (320 x 0.20 mm) |
|
| extinguishing,
resistant against |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
|
| mineral oils,
hydrolysis, microbes |
572-0100-003 |
3 |
0.57 |
14.5 |
572-0100-005 |
5 |
0.71 |
17.9 |
|
| Technical
Data: |
572-0100-004 |
4 |
0.64 |
16.1 |
|
|
|
|
|
| Rated voltage: |
6AWG (16.00 mm²) Stranding:
VDE 0295, class 6 (512 x 0.20 mm) |
|
| 300/500 Volt |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Test voltage: |
572-0160-004 |
4 |
0.75 |
18.9 |
|
|
|
|
|
| 3,000 Volt |
572-0160-005 |
5 |
0.82 |
20.8 |
|
|
|
|
|
| Bending
radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x
diameter |
|
|
|
|
|
|
|
|
|
| flexible
app.: 5 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
|
|
|
| fixed: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
| flex.: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|