CC-Schleppflex® PUR-571-UL
 
 
             
           
           
           
with filler if necessary Highflex   halogen-free          
Applications: 18AWG (1.00 mm²)  Stranding: VDE 0295, class 5  (32 x  0,20 mm)
Power supply chains Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Electical Equipments 571-18-02 2 0.37 9.3 571-18-18 18 0.78 19.7
Resistant to solvents, salt water 571-18-03 3 0.39 9.7 571-18-25 25 0.96 24.2
acids, oil, weather. 571-18-04 4 0.42 10.5 571-18-34 34 1.04 26.4
High mechanical stress 571-18-05 5 0.49 12.3 571-18-41 41 1.11 28.1
Specifications: 571-18-07 7 0.56 14.1 571-18-50 50 1.24 31.5
According to VDE 0250/0282  571-18-09 9 0.66 16.6        
UL style 20234 571-18-12 12 0.68 17.3        
CSA FT1, AMW I/II A/B VW-1 16AWG (1.50 mm²)  Stranding: VDE 0295, class 5  (30 x  0,25 mm)
Construction: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Conductors: 571-16-02 2 0.40 10.0 571-16-12 12 0.75 18.9
Bare copper strands acc. 571-16-03 3 0.42 10.5 571-16-18 18 0.85 21.6
to VDE 0295, class 5, with  571-16-04 4 0.45 11.4 571-16-25 25 1.06 26.8
TPE insulation 571-16-05 5 0.53 13.3 571-16-41 41 1.26 31.9
Color code: 571-16-07 7 0.61 15.3        
black conductors with white 571-16-09 9 0.72 18.1        
consec. numbers, cables with 14AWG (2.50 mm²)  Stranding: VDE 0295, class 5  (50 x  0,25 mm)
three or more conductors Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
with green/yellow ground  571-14-02 2 0.52 13.0 571-14-09 9 0.88 12.2
wire in the outer layer 571-14-03 3 0.54 13.7 571-14-12 12 0.95 24.0
Stranding: 571-14-04 4 0.59 14.8 571-14-18 18 1.09 27.7
cores twisted in layers 571-14-07 7 0.77 19.5 571-14-25 25 1.33 33.8
with very short lay lengths 12AWG (4.00 mm²)  Stranding: VDE 0295, class 5  (56 x  0,30 mm)
  Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Jacket: 571-12-03 3 0.63 15.9 571-12-05 5 0.75 18.9
PUR jacket black 571-12-04 4 0.69 17.5        
flame retardant and self- 10AWG (6.00 mm²)  Stranding: VDE 0295, class 5  (84 x  0,30 mm)
extinguishing, resistant against Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
mineral oils, hydrolysis, microbes 571-10-03 3 0.71 17.8 571-10-05 5 0.78 19.7
Technical Data: 571-10-04 4 0.76 19.3        
Rated voltage: 8AWG (10.00 mm²)  Stranding: VDE 0295, class 5  (80 x  0,40 mm)
600 Volt Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Test voltage: 571-08-04 4 1.00 25.5 571-08-05 5 1.09 27.7
3,000 Volt 6AWG (16.00 mm²)  Stranding: VDE 0295, class 5  (128 x  0,40 mm)
Bending radius: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
fixed: 5 x diameter 571-06-04 4 1.14 28.9 571-06-05 5 1.24 31.4
flexible app.: 5 x diameter 4AWG (25.00 mm²)  Stranding: VDE 0295, class 5  (200 x  0,40 mm)
Temperature range: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
fixed:    -58°F to 221°F  571-04-04 4 1.30 33.0        
flex.:     -58°F to 221°F