| CC-Schleppflex® PUR-C-568-UL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Highflex |
|
shielded |
|
halogen-free |
|
|
|
| Applications: |
18AWG (1.00 mm²) Stranding: VDE
0295, class 5 (32 x 0.20 mm) |
|
| Power supply
chains |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Control
devices |
568-18-03 |
3 |
0.40 |
10.0 |
568-18-12 |
12 |
0.69 |
17.6 |
|
| Whenever
elecrical interference |
568-18-04 |
4 |
0.42 |
10.7 |
568-18-18 |
18 |
0.79 |
20.0 |
|
| distorts
signal transmission. |
568-18-05 |
5 |
0.50 |
12.6 |
568-18-25 |
25 |
0.95 |
24.1 |
|
| Specifications: |
568-18-07 |
7 |
0.57 |
14.4 |
|
|
|
|
|
| According to
VDE 0250, 0282 |
16AWG (1.50 mm²) Stranding: VDE
0295, class 5 (30 x 0.25 mm) |
|
| UL style
20234 |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| CSA AWM I
A/B, II A/B FT 1 |
568-16-03 |
3 |
0.43 |
10.8 |
568-16-12 |
12 |
0.76 |
19.2 |
|
| Construction: |
568-16-04 |
4 |
0.46 |
11.6 |
568-16-18 |
18 |
0.87 |
22.0 |
|
| Conductors: |
568-16-05 |
5 |
0.54 |
13.6 |
568-16-25 |
25 |
1.07 |
27.2 |
|
| Bare copper
strands acc. |
568-16-07 |
7 |
0.62 |
15.6 |
|
|
|
|
|
| to VDE 0295, class 5, with |
14AWG (2.50 mm²) Stranding: VDE
0295, class 5 (50 x 0.25 mm) |
|
| TPE
insulation |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Color code: |
568-14-02 |
2 |
0.55 |
13.9 |
568-14-07 |
7 |
0.77 |
19.4 |
|
| black cond.
with white consec. |
568-14-03 |
3 |
0.60 |
15.1 |
|
|
|
|
|
| numbers,
cables with three or |
568-14-04 |
4 |
0.68 |
17.2 |
|
|
|
|
|
| more cond.
with yellow/green |
12AWG (4.00 mm²) Stranding: VDE
0295, class 5 (56 x 0.30 mm) |
|
| ground wire
in the outer layer |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Stranding: |
568-12-03 |
3 |
0.64 |
16.2 |
|
|
|
|
|
| cores
twisted in layers with |
568-12-04 |
4 |
0.69 |
17.5 |
|
|
|
|
|
| very short
lay lengths and fleece |
10AWG (6.00 mm²) Stranding: VDE
0295, class 5 (84 x 0.30 mm) |
|
| around
cores, plus common |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| shield and
inner jacket TPE |
568-10-03 |
3 |
0.72 |
18.1 |
|
|
|
|
|
| Jacket: |
568-10-04 |
4 |
0.77 |
19.6 |
|
|
|
|
|
| outer PUR
jacket, black |
568-10-05 |
5 |
0.79 |
20.1 |
|
|
|
|
|
| flame
retardant and self- |
8AWG (10.00 mm²) Stranding:
VDE 0295, class 5 (80 x 0.40 mm) |
|
|
| extinguishing,
resistant against |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| minaral
oils, salt water, weather, |
568-08-04 |
4 |
1.02 |
25.9 |
|
|
|
|
|
| solvents,
mechanical stress |
6AWG (16.00 mm²) Stranding:
VDE 0295, class 5 (128 x 0.40 mm) |
|
| Technical
Data: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Rated
voltage: |
568-06-04 |
4 |
1.15 |
29.3 |
|
|
|
|
|
| 600 Volt |
|
|
|
|
|
|
|
|
|
| Test
voltage: |
|
|
|
|
|
|
|
|
|
| 3,000 Volt |
|
|
|
|
|
|
|
|
|
| Bending
radius: |
|
|
|
|
|
|
|
|
|
| fixed: 5 x
diameter |
|
|
|
|
|
|
|
|
|
| flexible
app.: 7.5 x diameter |
|
|
|
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
|
|
|
| fixed: -58°F to 221°F |
|
|
|
|
|
|
|
|
|
| flex.: -58°F to 221°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|