CC-Tray Cable-TC-590-UL
 
 
             
           
           
           
with filler if necessary Highflex              
Applications: 18AWG (1.00 mm²)  Stranding: VDE 0295, class 5  (32 x  0.20 mm)
Open wiring on cable trays Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
and free laying on 590-1803 3 0.30 7.5 590-1812 12 0.48 12.1
machines and industrial 590-1804 4 0.32 8.1 590-1818 18 0.59 14.8
plants (340-4 NEC) 590-1805 5 0.35 8.9 590-1825 25 0.67 17.0
UV,Oil,Coolant resistant 590-1807 7 0.38 9.5        
Specifications: 590-1809 9 0.44 11.1        
According to VDE 0281  16AWG (1.50 mm²)  Stranding: VDE 0295, class 5  (30 x  0.25 mm)
UL style 2587 Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
AWM, VW-1 590-1603 3 0.32 8.1 590-1618 18 0.64 16.2
Construction: 590-1604 4 0.35 8.7 590-1625 25 0.74 18.7
Conductors: 590-1605 5 0.38 9.5 590-1641 41 0.97 24.5
Bare copper strands acc. 590-1607 7 0.41 10.2 590-1650 50 1.01 25.7
to VDE 0295, class 5, with  590-1609 9 0.47 11.8 590-1661 61 1.08 27.5
PVC insulation and transparent 590-1612 12 0.53 13.3        
nylon skin. 590-1616 16 0.61 15.4        
Color code: 14AWG (2.50 mm²)  Stranding: VDE 0295, class 5  (50 x  0.25 mm)
black conductors with white Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
consec. numbers, cables with 590-1403 3 0.35 8.8 590-1412 12 0.61 15.5
three and more cond. with gound 590-1404 4 0.38 9.6 590-1418 18 0.71 17.8
wire green/yellow 590-1405 5 0.41 10.4 590-1425 25 0.81 20.5
Stranding: 590-1407 7 0.45 11.3        
cores twisted in layers 590-1409 9 0.52 13.1        
  12AWG (4.00 mm²)  Stranding: VDE 0295, class 5  (56 x  0.30 mm)
Jacket: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
PVC jacket black 590-1204 4 0.45 11.4 590-1207 7 0.57 14.5
flame retardant and self- 590-1205 5 0.49 12.5        
extinguishing 10AWG (6.00 mm²)  Stranding: VDE 0295, class 5  (84 x  0.30 mm)
Technical Data: Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
Rated voltage: 590-1004 4 0.60 15.1 590-1007 7 0.71 17.9
600 Volt 590-1005 5 0.65 16.5        
Test voltage: 8AWG (10.00 mm²)  Stranding: VDE 0295, class 5  (80 x  0.40 mm)
4,000 volt Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
  590-0804 4 0.77 19.5        
Bending radius: 590-0805 5 0.89 22.6        
fixed: 5 x diameter 6AWG (16.00 mm²)  Stranding: VDE 0295, class 5  (128 x  0.40 mm)
flexible app.: 15 x diameter Part Numbers cond. O.D. inches O.D. mm Part Numbers cond. O.D. inches O.D. mm
  590-0604 4 0.90 22.8        
Temperature range: 590-0605 5 0.98 24.9        
fixed:    -40°F to 194°F                 
flex.:      23°F to 194°F