| CC-Servo Motor-supply (St) CY-588-UL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
Highflex |
|
shielded |
|
|
|
|
|
|
| Applications: |
22AWG (0.34 mm²) Stranding: VDE
0295, class 5 (19 x 0.15 mm) |
|
| Servo Motors |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Frequency
converters |
588-22-04 |
4 |
0.44 |
11.1 |
|
|
|
|
|
| Damp areas |
20AWG (0.50 mm²) Stranding: VDE
0295, class 5 (16 x 0.20 mm) |
|
| Whenever
electrical interference |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| distorts
signal transmission. |
588-20-04 |
4 |
0.46 |
11.6 |
|
|
|
|
|
| Specifications: |
18AWG (1.00 mm²) Stranding: VDE
0295, class 5 (32 x 0.20 mm) |
|
| According to VDE 0281 |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| UL-style
20886 |
588-18-04 |
4 |
0.48 |
12.2 |
|
|
|
|
|
| |
16AWG (1.50 mm²) Stranding: VDE
0295, class 5 (30 x 0.25 mm) |
|
| Construction: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Conductors: |
588-16-04 |
4 |
0.55 |
14.0 |
|
|
|
|
|
| Tinned copper
strands acc. |
14AWG (2.50 mm²) Stranding: VDE
0295, class 5 (50 x 0.25 mm) |
|
| to VDE 0295, class 5, with |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| PVC
insulation |
588-14-04 |
4 |
0.58 |
14.7 |
|
|
|
|
|
| |
12AWG (4.00 mm²) Stranding: VDE
0295, class 5 (56 x 0.30 mm) |
|
| Color code: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| black
conductors with white |
588-12-04 |
4 |
0.65 |
16.3 |
|
|
|
|
|
| consec.
numbers, cables with |
10AWG (6.00 mm²) Stranding: VDE
0295, class 5 (84 x 0.30 mm) |
|
| three and
more cond. with gound |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| wire
green/yellow |
588-10-04 |
4 |
0.78 |
19.8 |
|
|
|
|
|
| Stranding: |
8AWG (10.00 mm²) Stranding:
VDE 0295, class 5 (80 x 0.40 mm) |
|
| cores twisted
in layers with inner |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| PVC jacket,
plus foil and |
588-08-04 |
4 |
0.93 |
23.6 |
|
|
|
|
|
| braided
screen. |
6AWG (16.00 mm²) Stranding:
VDE 0295, class 5 (128 x 0.40 mm) |
|
| Jacket: |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| PVC outer
jacket orange, |
588-06-04 |
4 |
1.06 |
26.8 |
|
|
|
|
|
| flame
retardant and self- |
4AWG (25.00 mm²) Stranding:
VDE 0295, class 5 (200 x 0.40 mm) |
|
| extinguishing |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
|
| Technical
Data: |
588-04-04 |
4 |
1.27 |
32.2 |
|
|
|
|
|
| Rated voltage: |
2AWG (35.00 mm²) Stranding:
VDE 0295, class 5 (280 x 0.40 mm) |
|
| 1,000 Volt |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
Part Numbers |
cond. |
O.D. inches |
O.D. mm |
|
| Test voltage: |
588-02-04 |
4 |
1.45 |
36.9 |
|
|
|
|
|
| 7,500 Volt |
|
|
|
|
|
|
|
|
|
| Bending
radius: |
|
|
|
|
|
|
|
|
|
| fixed: 9 x
diameter |
|
|
|
|
|
|
|
|
|
| flexible
app.: 12 x diameter |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
|
|
|
| fixed: -13°F to 194°F |
|
|
|
|
|
|
|
|
|
| flex.: 23°F to 194°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|