| CC-Servo Motor-supply PUR-C-582-UL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
| Applications: |
|
|
|
|
|
|
| Power supply
chains |
Superflex |
power/data |
shielded |
|
| handling
equipments |
Power
19AWG (0.75 mm²)
Stranding: VDE 0295, class 6
(42 x 0.15 mm) |
|
| Oil and
hydrolysis resistant |
Data
22AWG (0.34 mm²)
Stranding: VDE 0295, class 6
(42 x 0.10 mm) |
|
| high
mechanical stress |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| Specifications: |
582-4007-2203-08 |
4 x 19AWG |
2 pairs 22AWG |
0.44 |
11.0 |
|
| According to VDE 0245/0281 |
|
|
|
|
|
|
| UL style
10264/20234 |
Power
18AWG (1.00 mm²)
Stranding: VDE 0295, class 6
(56 x 0.15 mm) |
|
| CSA style AWM
I A/B, II A/B FT 1 |
Data
19AWG (0.75 mm²)
Stranding: VDE 0295, class 6
(42 x 0.15 mm) |
|
| Construction: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| Conductors: |
582-4010-2207-08 |
4 x 18AWG |
2 pairs 19AWG |
0.48 |
12.0 |
|
| Fine bare
copper strands acc. |
|
|
|
|
|
|
| to VDE 0295, class 6, with |
Power
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| TPE insulation |
Data
20AWG (0.50 mm²)
Stranding: VDE 0295, class 6
(28 x 0.15 mm) |
|
| Color code: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| black
conductors with white |
582-4015-2205-08 |
4 x 16AWG |
2 pairs 20AWG |
0.48 |
12.1 |
|
| numbers 1, 2,
3 plus one ground |
|
|
|
|
|
|
| wire
green/yellow, pairs numb. |
Power
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| Stranding: |
Data
19AWG (0.75 mm²)
Stranding: VDE 0295, class 6
(42 x 0.15 mm) |
|
| cores twisted
in layers, pairs |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| shielded with
alu foil, drain wire |
582-4015-2207-08 |
4 x 16AWG |
2 pairs 19AWG |
0.48 |
12.1 |
|
| and braided
screen, wrapping, |
|
|
|
|
|
|
| fleece and
common shield around |
Power
14AWG (2.50 mm²)
Stranding: VDE 0295, class 6
(140 x 0.15 mm) |
|
| all wires |
Data
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| Jacket: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| PUR jacket
orange |
582-4025-2215-08 |
4 x 14AWG |
2 pairs 16AWG |
0.60 |
15.1 |
|
| flame
retardant and self- |
|
|
|
|
|
|
| extinguishing |
Power
12AWG (4.00 mm²)
Stranding: VDE 0295, class 6
(224 x 0.15 mm) |
|
| Technical
Data: |
Data
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| Rated
voltage: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| 1,000 Volt |
582-4040-2215-08 |
4 x 12AWG |
2 pairs 16AWG |
0.71 |
17.8 |
|
| Test voltage: |
|
|
|
|
|
|
| Power cores
4,000 Volt |
Power
10AWG (6.00 mm²)
Stranding: VDE 0295, class 6
(102 x 0.20 mm) |
|
| Control cores
2,000 Volt |
Data
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
|
| Bending
radius: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| fixed: 5 x
diameter |
582-4060-2215-08 |
4 x 10AWG |
2 pairs 16AWG |
0.71 |
18.0 |
|
| flexible
app.: 7.5 x diameter |
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
| fixed: -22°F to 176°F |
|
|
|
|
|
|
| flex.: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|