| CC-Servo Motor-supply PUR-C-582-UL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| with filler if necessary |
|
|
|
|
|
|
| Applications: |
|
|
|
|
|
|
| Power supply
chains |
Superflex |
power/data |
shielded |
|
| handling
equipments |
Power
8AWG (10.00 mm²)
Stranding: VDE 0295, class 6 (320 x
0.20 mm) |
|
| Oil and
hydrolysis resistant |
Data
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| high
mechanical stress |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| Specifications: |
582-4100-2215-08 |
4 x 8AWG |
2 pairs 16AWG |
0.44 |
11.0 |
|
| According to VDE 0245/0281 |
|
|
|
|
|
|
| UL style
10264/20234 |
Power
6AWG (16.00 mm²)
Stranding: VDE 0295, class 6 (512 x
0.20 mm) |
|
| CSA style AWM
I A/B, II A/B FT 1 |
Data
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| Construction: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| Conductors: |
582-4160-2215-08 |
4 x 6AWG |
2 pairs 16AWG |
1.06 |
26.8 |
|
| Fine bare
copper strands acc. |
|
|
|
|
|
|
| to VDE 0295, class 6, with |
Power
4AWG (25.00 mm²)
Stranding: VDE 0295, class 6 (800 x
0.20 mm) |
|
| TPE insulation |
Data
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| Color code: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| black
conductors with white |
582-4250-2215-08 |
4 x 4AWG |
2 pairs 16AWG |
1.15 |
29.2 |
|
| numbers 1, 2,
3 plus one ground |
|
|
|
|
|
|
| wire
green/yellow, pairs numb. |
Power
2AWG (35.00 mm²) Stranding: VDE 0295, class 6 (1120 x 0.20 mm) |
|
| Stranding: |
Data
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| cores twisted
in layers, pairs |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| shielded with
alu foil, drain wire |
582-4350-2215-08 |
4 x 2AWG |
2 pairs 16AWG |
1.28 |
32.4 |
|
| and braided
screen, wrapping, |
|
|
|
|
|
|
| fleece and
common shield around |
Power
1AWG (50.00 mm²) Stranding: VDE 0295, class 6 (705 x 0.30 mm) |
|
| all wires |
Data
14AWG (2.50 mm²)
Stranding: VDE 0295, class 6
(140 x 0.15 mm) |
|
| Jacket: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| PUR jacket
orange |
582-4500-2225-08 |
4 x 1AWG |
2 pairs 14AWG |
1.46 |
37.0 |
|
| flame
retardant and self- |
|
|
|
|
|
|
| extinguishing |
Power
16AWG (1.50 mm²) Stranding: VDE 0295, class 6 (84 x 0.15 mm) |
|
| Technical
Data: |
Data
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| Rated
voltage: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| 1,000 Volt |
582-4015-215-08 |
4 x 16AWG |
1 pair 16AWG |
0.48 |
12.0 |
|
| Test voltage: |
|
|
|
|
|
|
| Power cores
4,000 Volt |
Power
14AWG (2.50 mm²) Stranding: VDE 0295, class 6 (140 x 0.15 mm) |
|
| Control cores
2,000 Volt |
Data
16AWG (1.50 mm²)
Stranding: VDE 0295, class 6
(84 x 0.15 mm) |
|
| Bending
radius: |
Part Numbers |
power cond. |
shld. pairs |
O.D inches |
O.D. mm |
|
| fixed: 5 x
diameter |
582-4025-215-08 |
4 x 14AWG |
1 pair 16AWG |
0.51 |
12.8 |
|
| flexible
app.: 7.5 x diameter |
|
|
|
|
|
|
| Temperature
range: |
|
|
|
|
|
|
| fixed: -22°F to 176°F |
|
|
|
|
|
|
| flex.: -22°F to 176°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|